Difference between revisions of "Man ImplantAlign"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(Marked this version for translation)
 
(16 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<languages/>
+
{{Language bar}}
{{DISPLAYTITLE:Implant Alignment}}
+
{{DISPLAYTITLE:Marker Alignment|noerror}}
 
<translate>
 
<translate>
= Implant Acquisition = <!--T:1-->
+
= Marker Acquisition = <!--T:1-->
  
 
<!--T:8-->
 
<!--T:8-->
When you acquire the data for a project above implants, acquiring the implant itself is really difficult. It's not like a stump or a piece o stone model. The implant connection/interfaces normally are small and metallic.  
+
When acquiring the data for a project on implants, acquiring the implant itself is problematic. It's not like a stump or a piece of stone model. The implant connections/interfaces are normally small and metallic.  
  
 
<!--T:9-->
 
<!--T:9-->
More than this the fitting need to be mechanically perfect, there is close to no margin of error.
+
Moreover, the fitting has to be mechanically perfect, with no margin of error.
  
 
<!--T:10-->
 
<!--T:10-->
To solve this problem you're not going to scan directly the implant connection but an '''Implant Marker''', a specific object designed to be scanned that fit exactly over the implant you need.
+
To solve this problem, the implant connection is not directly scanned but an '''Implant Marker or Scan Body''' is used in its stead. A Scan Body is a specific object, designed to be scanned, which fits exactly over the implant.
  
 
<!--T:11-->
 
<!--T:11-->
The scan of the implant marker is not enough to work. You need to use this data to compute the exact position of the implant interface. For this you need an [[Implant_Library|Implant Library]].  
+
The scan of the implant marker itself is not enough: its resulting data will be used to compute the exact position of the implant interface. In order to carry out this operation, an [[Implant_Library|Implant Library]] is needed .  
  
 
<!--T:12-->
 
<!--T:12-->
This can be done directly in the CAD software, but if you're using an implant library for the Exocad Platform OpticalRevEng Dental can let you do this alignment directly in the scan software to get better results.
+
The alignment to the implant library can be performed in the CAD software. However, using an implant library for Exocad's Platform, the user can perform this operation directly in the scanning software OpticalRevEng Dental, in order to get better results.
  
 
= Implant Selection = <!--T:13-->
 
= Implant Selection = <!--T:13-->
  
 
<!--T:14-->
 
<!--T:14-->
After the mesh generation, if you select the mesh of an implant marker from the project tree, the ''Implant Alignment'' button will appear in the [[Main_Toolbar|Main Toolbar]].
+
After the mesh generation, by selecting the mesh of an implant marker from the project tree, the ''Marker Alignment'' button will appear in the [[Main_Toolbar|Main Toolbar]].
You can then click on this button to open the ''Implant Selection'' dialog.
+
Click on this button to open the ''Implant Selection'' dialog.
  
 
<!--T:15-->
 
<!--T:15-->
[[File:Dental_2_5_implantSelection.jpg|upright|center]]
+
[[File:Dental_3_5_implantSelection.JPG]]
  
 
<!--T:16-->
 
<!--T:16-->
This dialog is made by:
+
In this Dialog there are:
  
 
<!--T:17-->
 
<!--T:17-->
# A tooth position selection (the button with three dots ...) that can be used, only in [[Free_Mode|Free Mode]] to select the tooth position of one implant
+
# A tooth position selection (Change ...) that can be used only in [[Free_Mode|Free Mode]] to select the tooth position of an implant
# An implant list with all the implants availables in the current implant library
+
# A '''Select Library''' button, that opens the Library Selection Panel
# A Filter box where you can put part of the name of the implant you need and all the implants that match the name will be showed in the implant list
+
# A Marker Preview menu that, once the appropriate connection has been selected for the current element, will show the STL of the marker present in the library. It is possible to choose different views to check the Merker's shape
  
 
<!--T:18-->
 
<!--T:18-->
You just need to select the implant you want to use and click the '''Select''' Button.
+
To continue with the Marker selection click on the '''Select Library''' Button. The '''Implant Selection Panel''' will open. The Panel is divided in 4 Sections
  
<!--T:2-->
+
<!--T:23-->
Choosing the right implant from the library need care. Many implant libraries have different ''versions'' of every implant connection.  For example you can find:
+
[[File:Dental_3_5_implantSelectionPanel.JPG]]
  
<!--T:19-->
+
<!--T:24-->
* Engaging Connections : The connection used can not rotate over the implant, for abutments or single restorations
+
'''Library'''
* Not-Engaging Connections : The connection used can rotate over the implant, for bars and bridges
+
 
* For Zirconia : Connections with particular shapes, suited for zirconia restorations
+
<!--T:25-->
 +
For choosing the general connection and implant family, contains:
 +
 
 +
<!--T:26-->
 +
# A Filter box where it is possible to write part of the name of the needed implant. All the implants that match the name will be showed in the implant list
 +
# An implant list with all the implants available in the current Implant Library
 +
 
 +
<!--T:27-->
 +
'''Type and Sub Type'''
 +
 
 +
<!--T:28-->
 +
For Choosing the diameter and type of connection. There can be many of these types, in our libraries for instance there are:
 +
 
 +
<!--T:29-->
 +
* Engaging Connections : the connection can not rotate on the implant, suggested for abutments or single restorations
 +
* Not-Engaging Connections : the connection can rotate on the implant, suggested for bars and bridges
 +
* For Zirconia : connections with specific shapes, suited for zirconia restorations
 +
 
 +
<!--T:30-->
 +
'''Preview'''
 +
 
 +
<!--T:31-->
 +
Shows the preview of the STL marker present in the library
 +
 
 +
<!--T:32-->
 +
'''Info'''
 +
 
 +
<!--T:33-->
 +
If the library is correctly configured to work with our software, in this section it is possible to have a small overview of the libraries with additional information on the availabe diameters and implant types.
 +
All our libraries are provided with this feature and, being connected to this wiki, the ''Open in browser'' button opens the wiki on the implant list page.
 +
 
 +
<!--T:34-->
 +
To accept the implant selection click on ''Select'', otherwise ''Cancel''.
  
 
<!--T:3-->
 
<!--T:3-->
If you select the wrong implant you can do again all the procedure to replace the old connection aligned with a new one.  
+
If the wrong implant is selected, it is possible to repeat the procedure to replace the old aligned connection with a new one.  
  
 
<!--T:20-->
 
<!--T:20-->
'''If you start the CAD design with a wrong connection you'll need to redo all the design from the start'''
+
'''If the CAD design is launched using a wrong connection it will be necessary to restart all the design from the beginning'''
  
= Implant Alignment = <!--T:4-->
+
= Marker Alignment = <!--T:4-->
  
 
<!--T:21-->
 
<!--T:21-->
When you select the implant connection you want to use the software will enter in the [[Man_Align#Manual Alignment|Manual Alignment]] mode.
+
When selecting the implant connection, the software will start the [[Man_Align#Manual Alignment|Manual Alignment]] mode.
  
 
<!--T:5-->
 
<!--T:5-->
You'll have to align the marker acquried mesh with the library marker shape. From this data the connection position will be computed
+
The acquired marker mesh will need to be aligned to the library marker shape. From this data the connection position will be computed.
  
 
<!--T:6-->
 
<!--T:6-->
This procedure needs to be done for every implant in the project. The [[Man_DataExport|CAD Export]] will issue a warning if miss one or more implant alignments.
+
This procedure has to be performed for every marker of the project. The [[Man_DataExport|CAD Export]] will issue a warning if one or more marker alignments are missing.
 
 
=Next= <!--T:7-->
 
  
<!--T:22-->
 
Now that you know how to align an implant acquisition to the implant library you can return to the [[Main_Page|Main Page]] or read about [[Man_DataExport|Export]] functions.
 
 
</translate>
 
</translate>
 +
{{Navigation|Man_MeshEditing|Man_DataExport}}

Latest revision as of 09:49, 21 June 2016


Marker Acquisition

When acquiring the data for a project on implants, acquiring the implant itself is problematic. It's not like a stump or a piece of stone model. The implant connections/interfaces are normally small and metallic.

Moreover, the fitting has to be mechanically perfect, with no margin of error.

To solve this problem, the implant connection is not directly scanned but an Implant Marker or Scan Body is used in its stead. A Scan Body is a specific object, designed to be scanned, which fits exactly over the implant.

The scan of the implant marker itself is not enough: its resulting data will be used to compute the exact position of the implant interface. In order to carry out this operation, an Implant Library is needed .

The alignment to the implant library can be performed in the CAD software. However, using an implant library for Exocad's Platform, the user can perform this operation directly in the scanning software OpticalRevEng Dental, in order to get better results.

Implant Selection

After the mesh generation, by selecting the mesh of an implant marker from the project tree, the Marker Alignment button will appear in the Main Toolbar. Click on this button to open the Implant Selection dialog.

Dental 3 5 implantSelection.JPG

In this Dialog there are:

  1. A tooth position selection (Change ...) that can be used only in Free Mode to select the tooth position of an implant
  2. A Select Library button, that opens the Library Selection Panel
  3. A Marker Preview menu that, once the appropriate connection has been selected for the current element, will show the STL of the marker present in the library. It is possible to choose different views to check the Merker's shape

To continue with the Marker selection click on the Select Library Button. The Implant Selection Panel will open. The Panel is divided in 4 Sections

Dental 3 5 implantSelectionPanel.JPG

Library

For choosing the general connection and implant family, contains:

  1. A Filter box where it is possible to write part of the name of the needed implant. All the implants that match the name will be showed in the implant list
  2. An implant list with all the implants available in the current Implant Library

Type and Sub Type

For Choosing the diameter and type of connection. There can be many of these types, in our libraries for instance there are:

  • Engaging Connections : the connection can not rotate on the implant, suggested for abutments or single restorations
  • Not-Engaging Connections : the connection can rotate on the implant, suggested for bars and bridges
  • For Zirconia : connections with specific shapes, suited for zirconia restorations

Preview

Shows the preview of the STL marker present in the library

Info

If the library is correctly configured to work with our software, in this section it is possible to have a small overview of the libraries with additional information on the availabe diameters and implant types. All our libraries are provided with this feature and, being connected to this wiki, the Open in browser button opens the wiki on the implant list page.

To accept the implant selection click on Select, otherwise Cancel.

If the wrong implant is selected, it is possible to repeat the procedure to replace the old aligned connection with a new one.

If the CAD design is launched using a wrong connection it will be necessary to restart all the design from the beginning

Marker Alignment

When selecting the implant connection, the software will start the Manual Alignment mode.

The acquired marker mesh will need to be aligned to the library marker shape. From this data the connection position will be computed.

This procedure has to be performed for every marker of the project. The CAD Export will issue a warning if one or more marker alignments are missing.

Dental 2 5 wiz prev.png Homebutton.png Dental 2 5 wiz next.png