= Acquisitions = <!--T:1-->
= Acquisitions =
 
Acquiring data from the scanner and create a virtual 3D representation of an object is the primary function of the OpticalRevEng Dental software.
 
  
If you're working using the Step-By-Step Wizard you can look at [[Wiz_Acquisition|Wizard Acquisition]] page.
+
<!--T:10-->
 +
Acquiring data from the scanner and creating a virtual 3D representation of an object is the primary function of the OpticalRevEng Dental software.
  
In a '''Structured Project''' outside of the wizard you have 3 way to acquire data from the scanner.
+
<!--T:2-->
== Simple ==
+
For additional information about the Step-By-Step Wizard, check the [[Wiz_Acquisition|Wizard Acquisition]] page.
This is the most simple way to acquire data, and the one you'll use the most. You just have to:
+
 
# Put the object inside the scanner over the appropiate model holder
+
<!--T:11-->
# Select the object you want to scan in the ''Project Tree''
+
In a '''Structured Project''' outside the wizard, there are 3 procedures to acquire data from the scanner.
# Click the Acquisition button on the [[Main_Toolbar|Main Toolbar]]
+
 
The scanner will then acquire the object inside with the strategy of the selected element and update the status of the ''Project Tree''
+
== Simple == <!--T:3-->
[[File:Denta_2_5_simpleAcquisition.gif|center]]
+
 
== Multi-Die ==
+
<!--T:12-->
If you want to acquire multiple dies in one scan using the multi-die support holder yo have to:
+
This is the easiest way to acquire data, and the most used:
# Select from the ''Project Tree'' all the dies you want to scan
+
 
# Click the Multi-Die Acquisition button that will appear on the [[Main_Toolbar|Main Toolbar]] as soon as at least 2 dies are selected in the ''Project Tree''
+
<!--T:13-->
# Put the dies in the support as the software will show on the Top Right window and put the Multi-Die support inside the scanner
+
# Put the object inside the scanner on the appropriate model holder
 +
# In the ''Project Tree'', select the object to scan
 +
# Click the Acquisition icon on the [[Main_Toolbar|Main Toolbar]]
 +
 
 +
<!--T:14-->
 +
The scanner will then acquire the object using the strategy of the selected element and the status of the ''Project Tree'' will be updated.
 +
 
 +
<!--T:15-->
 +
[[File:Denta_2_5_simpleAcquisition.gif]]
 +
 
 +
<!--T:56-->
 +
If the models are prepared to be mounted in an articulator, they could be too tall to be mounted on the tall model holder and be properly focused by the scanner. For this reason, the model holder base can be detached from the plate itself to allow the user to scan taller models on the low support.
 +
 
 +
<!--T:57-->
 +
[[File:piattello-da-staccare.jpg]]
 +
[[File:piattello-staccato.jpg]]
 +
 
 +
=== Advanced Parameters === <!--T:49-->
 +
 
 +
<!--T:50-->
 +
To use an acquisition strategy different from the default, hold the {{Inline button|Key shift.png}} button when clicking on the Acquisition icon.
 +
 
 +
<!--T:51-->
 +
[[File:Adv-acqui.JPG]]
 +
 
 +
<!--T:52-->
 +
An addittional dialog will allow to choose a different strategy and a color for the object that needs to be acquired
 +
 
 +
=== Dynamic Articulation === <!--T:53-->
 +
 
 +
<!--T:45-->
 +
If the '''Dynamic Articulation Module''' is enabled and in use, the software will remind the user to scan the jaw on top of the adequate base.
 +
 
 +
<!--T:46-->
 +
[[File:Msg art.PNG]]
 +
 
 +
<!--T:47-->
 +
The base to be used depends on the '''type of articulator''' chosen in the project definition.
 +
 
 +
<!--T:48-->
 +
{{Important|If the base type doesn't match the type of articulator, the positioning in Exocad Virtual Articulator won't be correct.}}
 +
 
 +
== Multi-Die == <!--T:16-->
 +
 
 +
<!--T:17-->
 +
To acquire multiple dies in a single scan, even from both jaws at the same time, using the multi-die support:
 +
 
 +
<!--T:18-->
 +
# Select from the ''Project Tree'' all the dies to be scanned
 +
# Click the Multi-Die Acquisition button that will appear on the [[Main_Toolbar|Main Toolbar]]. At least 2 dies have to be selected in the ''Project Tree''
 +
# Put the dies in each space of the support, as shown by the software in the top right window, and put the Multi-Die support inside the scanner
 
# Click the ''Start Acquisition'' button
 
# Click the ''Start Acquisition'' button
The scanner will acquire the data, identify every single die and update the status of the ''Project Tree''
+
 
[[File:Dental_2_5_multiDieAcquisition.gif|center]]
+
<!--T:19-->
== Single ==
+
The scanner will acquire the data, identifying every single die and updating the status of the ''Project Tree''
If you need to acquire a single 3d image and not a 360° object recostruction (for test or to acquire a big articulation in a small scanner) you can:
+
 
# Put the object inside the scanner in the best way possible
+
<!--T:20-->
 +
[[File:Dental_2_5_multiDieAcquisition.gif]]
 +
 
 +
== Single == <!--T:21-->
 +
 
 +
<!--T:22-->
 +
To acquire a single 3D image, and not a 360° object reconstruction (for testing or to acquire a big articulation in a small scanner):
 +
 
 +
<!--T:23-->
 +
# Put the object inside the scanner, in the best possible way  
 
# Use the [[Support_Toolbars_And_Menus#Tools|Single Acquisition]] tool
 
# Use the [[Support_Toolbars_And_Menus#Tools|Single Acquisition]] tool
The software will do a single acquisition without moving the manipulator
 
= Integration =
 
After you've acquired an object from the scanner, you may want to add further information from the startign scan. For example part of the object may be missing due to shadows or because the acquisition strategy has not covered a specific point of view that you need.
 
  
For integrate additional information you can use the Integrate Acquisition button on the [[Main_Toolbar|Main Toolbar]]. This will start the ''Integration Mode'' that gives you 3 different integration tools. You can pass from one tool to the other all the times you want. When you've finished you can confirm the modification with the Apply [[File:Dental_2_5_confirmButton.png|x35px]] button or discard everything with the Cancel [[File:Dental_2_5_cancelButton.png|x35px]] button.
+
<!--T:24-->
 +
The software will carry out a single acquisition without moving the motors system
 +
 
 +
= Integration = <!--T:25-->
 +
 
 +
<!--T:26-->
 +
After an object has been acquired in the scanner, there could be the need to add further information to the starting scan. For example, part of the object may be missing due to shadows or because the acquisition strategy has not covered a specific point of view.
 +
 
 +
<!--T:4-->
 +
In order to integrate additional information, use the '''Integrate Acquisition''' button on the [[Main_Toolbar|Main Toolbar]]. This will launch the ''Integration Mode'', providing 3 different integration tools. It is possible to switch from one tool to another. Confirm the modification with the '''Apply''' {{Inline button|AcceptButton.jpg}} button or discard it with the '''Cancel''' {{Inline button|Dental_2_5_cancelButton.png}} button.
 +
 
 +
<!--T:27-->
 +
It is possible to add an unlimited number of acquisitions but '''adding to much data could slow down the project and increase the project disk size'''.
 +
 
 +
== Single == <!--T:5-->
 +
 
 +
<!--T:28-->
 +
The single integration mode allows to add information from a specific point of view. To add information:
 +
 
 +
<!--T:29-->
 +
# Rotate the 3D view so that the screen will show exactly the part of the object to be integrated
 +
# Click on the Start Integration {{Inline button|Dental_2_5_startIntegrationButton.png}} icon
 +
 
 +
<!--T:54-->
 +
If you wish for the plate to replicate the virtual movements you apply to the image, check the '''Follow 3d View''' Box
 +
 
 +
<!--T:6-->
 +
If the last added acquisition is not good, useless or problematic, it is possible to remove it with the '''Undo''' {{Inline button|Dental_2_5_undoLastIntegrationBtn.png}} button.
 +
 
 +
<!--T:30-->
 +
If the object is not in the original scanning position, the software can not correctly integrate the information. It is possible to try to fix this problem using the ''Calc Integration Position'' button.
 +
 
 +
<!--T:31-->
 +
{{Screenshot|dental_3_5_integrateSingle.jpg}}
 +
 
 +
== Smart == <!--T:7-->
 +
 
 +
<!--T:32-->
 +
The Smart mode, instead of scanning one position at a time, allows to identify the holes on the virtual model and, if possible, close them with a scanning sequence. <br />
  
You can add all the additional acquisition you want but '''adding to much data can slow down the project and increase the project disk size'''
+
<!--T:33-->
== Single ==
+
To add a position:
The single integration mode let you add information from a specific point of view. To add information you just need to:
 
# Rotate the 3D view in a way that the screen show exactly the part you want to integrate
 
# Click the Start Integration [[File:Dental_2_5_startIntegrationButton.png|x35px]] button
 
  
If the last added acquisition is not good, not needed or has some problem you can remove it with the Undo [[File:Dental_2_5_undoLastIntegrationBtn.png|x35px]] button.
+
<!--T:34-->
 +
# Rotate the 3D view to identify the holes, and left click on the ones that need to be closed
 +
# Click the {{Inline button|Dental_2_5_startIntegrationButton.png}}  button to start the integration sequence
  
If the object is not in the original scannin position the software can not integrate the information correctly. You can try to fix this using the ''Calc Integration Position'' Button
+
<!--T:55-->
[[File:dental_2_5_integrateSingle.jpg|upright|center]]
+
The images will be added to the scan and then aligned all together at the end of the acquisition
== Custom ==
 
In custom mode, instead to scan one position at a time, you can create a personalized sequence of position and then let the scanner do all the acquisitions togheter. <br />
 
To add a position you have to:
 
# Rotate the 3D view in a way that the screen show exactly the part you want to integrate
 
# Click the Add Position [[File:Dental_2_5_confirmButton.png|x35px]] button
 
To remove a position you have to:
 
# Select the position from the list
 
# Click the Remove Position [[File:Dental_2_5_cancelButton.png|x35px]] button
 
To start the scan you have to click the Start Integration [[File:Dental_2_5_startIntegrationButton.png|x35px]] button
 
[[File:dental_2_5_integrateMulti.jpg|upright|center]]
 
== Full==
 
The full integration is the simplies. You select how much positions you want to take and how much you want to tilt the model. <br />
 
Then when you click the Start Integration [[File:Dental_2_5_startIntegrationButton.png|x35px]] button the scanner will tilt the model and do a 360° acquisition using the number of positions selected.
 
[[File:dental_2_5_integrateFull.jpg|upright|center]]
 
  
= Change Strategy =
+
<!--T:38-->
When the ''Project Tree'' is created the software will select a specific strategy for every element in the project trying to maximize the scan quality and saving space. If you need to change the strategy for a specific element of the project you can:
+
{{Screenshot|dental_3_5_integrateMulti.JPG}}
 +
 
 +
== Full== <!--T:39-->
 +
 
 +
<!--T:40-->
 +
The full integration is the easiest mode: it allows to select as many positions as needed and in which degree the plate must tilt to complete the image. <br />
 +
Then, by clicking the Start Integration [[File:Dental_2_5_startIntegrationButton.png|x35px]] button, the scanner will tilt the model and carry out a 360° acquisition using the selected number of positions.
 +
 
 +
<!--T:41-->
 +
{{Screenshot|dental_3_5_integrateFull.JPG}}
 +
 
 +
= Change Strategy = <!--T:8-->
 +
 
 +
<!--T:42-->
 +
When the ''Project Tree'' is created, the software will select a specific strategy for every element, trying to maximize the scan quality and saving space. To change the strategy of an element of the project:
 +
 
 +
<!--T:43-->
 
# Right click on the element in the project tree
 
# Right click on the element in the project tree
# Select Change Strategy
+
# Select ''Change Strategy''
# Select the new strategy from the dropdown menù
+
# Select the new strategy from the dropdown menu
If you scan again the object you'll see that the scanner will use the new strategy instead of the old one
+
 
 +
<!--T:44-->
 +
Another scan of the object will be carried out using the new strategy instead of the old one.
  
Now that you know how to acquire data from the scanner you can return to the [[Main_Page|Main Page]] or continue to the [[Man_DataEditing|Data Editing]] page
 
 
</translate>
 
</translate>
 +
{{Navigation|Man_ProjctCreation|Man_DataEditing}}

Latest revision as of 10:35, 7 September 2016


Acquisitions

Acquiring data from the scanner and creating a virtual 3D representation of an object is the primary function of the OpticalRevEng Dental software.

For additional information about the Step-By-Step Wizard, check the Wizard Acquisition page.

In a Structured Project outside the wizard, there are 3 procedures to acquire data from the scanner.

Simple

This is the easiest way to acquire data, and the most used:

  1. Put the object inside the scanner on the appropriate model holder
  2. In the Project Tree, select the object to scan
  3. Click the Acquisition icon on the Main Toolbar

The scanner will then acquire the object using the strategy of the selected element and the status of the Project Tree will be updated.

Denta 2 5 simpleAcquisition.gif

If the models are prepared to be mounted in an articulator, they could be too tall to be mounted on the tall model holder and be properly focused by the scanner. For this reason, the model holder base can be detached from the plate itself to allow the user to scan taller models on the low support.

Piattello-da-staccare.jpg Piattello-staccato.jpg

Advanced Parameters

To use an acquisition strategy different from the default, hold the Key shift.png button when clicking on the Acquisition icon.

Adv-acqui.JPG

An addittional dialog will allow to choose a different strategy and a color for the object that needs to be acquired

Dynamic Articulation

If the Dynamic Articulation Module is enabled and in use, the software will remind the user to scan the jaw on top of the adequate base.

Msg art.PNG

The base to be used depends on the type of articulator chosen in the project definition.

If the base type doesn't match the type of articulator, the positioning in Exocad Virtual Articulator won't be correct.

Multi-Die

To acquire multiple dies in a single scan, even from both jaws at the same time, using the multi-die support:

  1. Select from the Project Tree all the dies to be scanned
  2. Click the Multi-Die Acquisition button that will appear on the Main Toolbar. At least 2 dies have to be selected in the Project Tree
  3. Put the dies in each space of the support, as shown by the software in the top right window, and put the Multi-Die support inside the scanner
  4. Click the Start Acquisition button

The scanner will acquire the data, identifying every single die and updating the status of the Project Tree

Dental 2 5 multiDieAcquisition.gif

Single

To acquire a single 3D image, and not a 360° object reconstruction (for testing or to acquire a big articulation in a small scanner):

  1. Put the object inside the scanner, in the best possible way
  2. Use the Single Acquisition tool

The software will carry out a single acquisition without moving the motors system

Integration

After an object has been acquired in the scanner, there could be the need to add further information to the starting scan. For example, part of the object may be missing due to shadows or because the acquisition strategy has not covered a specific point of view.

In order to integrate additional information, use the Integrate Acquisition button on the Main Toolbar. This will launch the Integration Mode, providing 3 different integration tools. It is possible to switch from one tool to another. Confirm the modification with the Apply AcceptButton.jpg button or discard it with the Cancel Dental 2 5 cancelButton.png button.

It is possible to add an unlimited number of acquisitions but adding to much data could slow down the project and increase the project disk size.

Single

The single integration mode allows to add information from a specific point of view. To add information:

  1. Rotate the 3D view so that the screen will show exactly the part of the object to be integrated
  2. Click on the Start Integration Dental 2 5 startIntegrationButton.png icon

If you wish for the plate to replicate the virtual movements you apply to the image, check the Follow 3d View Box

If the last added acquisition is not good, useless or problematic, it is possible to remove it with the Undo Dental 2 5 undoLastIntegrationBtn.png button.

If the object is not in the original scanning position, the software can not correctly integrate the information. It is possible to try to fix this problem using the Calc Integration Position button.

Dental 3 5 integrateSingle.jpg

Smart

The Smart mode, instead of scanning one position at a time, allows to identify the holes on the virtual model and, if possible, close them with a scanning sequence.

To add a position:

  1. Rotate the 3D view to identify the holes, and left click on the ones that need to be closed
  2. Click the Dental 2 5 startIntegrationButton.png button to start the integration sequence

The images will be added to the scan and then aligned all together at the end of the acquisition

Dental 3 5 integrateMulti.JPG

Full

The full integration is the easiest mode: it allows to select as many positions as needed and in which degree the plate must tilt to complete the image.
Then, by clicking the Start Integration Dental 2 5 startIntegrationButton.png button, the scanner will tilt the model and carry out a 360° acquisition using the selected number of positions.

Dental 3 5 integrateFull.JPG

Change Strategy

When the Project Tree is created, the software will select a specific strategy for every element, trying to maximize the scan quality and saving space. To change the strategy of an element of the project:

  1. Right click on the element in the project tree
  2. Select Change Strategy
  3. Select the new strategy from the dropdown menu

Another scan of the object will be carried out using the new strategy instead of the old one.