Difference between revisions of "Dental Service Tools/ro"
(Created page with "Există 2 tipuri de calibrare: ; Recalibrare: procedură rapidă pentru a actualiza periodic calibrarea scanerului sau pentru a fi efectuată dacă scanerul este mutat în ori...") |
(Created page with "Acest instrument utilizează setul Calibration Kit pentru a efectua o nouă calibrare a capului optic al scanerului. Procedura este următoarea:") |
||
Line 27: | Line 27: | ||
; Calibrarea completă: Procedura mai complexă trebuie efectuată după o reparație mecanică | ; Calibrarea completă: Procedura mai complexă trebuie efectuată după o reparație mecanică | ||
− | + | Acest instrument utilizează setul [[Accessories|Calibration Kit]] pentru a efectua o nouă calibrare a capului optic al scanerului. Procedura este următoarea: | |
#Put the calibration kit inside the scanner in the correct position | #Put the calibration kit inside the scanner in the correct position |
Revision as of 05:03, 12 September 2017
Contents
Optical RevEnge Dental oferă un mod de service care poate fi deschis din Tools Menu, pentru a recalibra și a diagnostica orice problemă care ar putea apărea.
Modul Live
Cu acest instrument este posibil să verificați vizualizarea live a camerelor scanerului.
Pentru a porni acest instrument, faceți clic pe butonul ;
Verificați Scanerul
Software-ul verifică dacă conexiunea scanerului este în ordine de fiecare dată când este activată.
Cu ajutorul acestui instrument este posibilă rularea manuală a acestei verificări.
Recalibrați Capul
Pentru a lansa acest instrument, faceți clic pe butonul ;
Există 2 tipuri de calibrare:
- Recalibrare
- procedură rapidă pentru a actualiza periodic calibrarea scanerului sau pentru a fi efectuată dacă scanerul este mutat în orice altă locație
- Calibrarea completă
- Procedura mai complexă trebuie efectuată după o reparație mecanică
Acest instrument utilizează setul Calibration Kit pentru a efectua o nouă calibrare a capului optic al scanerului. Procedura este următoarea:
- Put the calibration kit inside the scanner in the correct position
- Select the calibration type from the drop-down menu
- In the calibration dialog, select from the drop down menu the exact calibration kit name
- Click Start
If the calibration kit name is not available in the drop down menu, the Load New Master Xml button can be used to add a new calibration kit from the appropriate Xml description file.
The calibration procedure is automatic. Once finished, the software will show one of the following messages:
- 'Scanner Already Calibrated' : the calibration is not necessary
- 'Scanner Recalibrated Successfully' : the calibration has been completed
- 'Scanner Recalibration Failed' : calibration has to be repeated
If the calibration was successful, the Axes Calibration starts automatically.
Recalibrate Axis
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.
This tool will start automatically after a Head Recalibration or can be started manually with the button.
- Put the calibration object inside the scanner
- Click Recalibrate Axis
- Click Ok when prompted
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:
- 'Axis Recalibration Successfull' : the calibration has been completed
- 'Axis Recalibration Failed' : calibration has to be repeated
Auto Set-Up Multi-Die Parameters
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:
- Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others
- Put the empty multi-die support inside the scanner
- Start the tool with this button
- Click Ok when prompted
Diagnostic Acquisition
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.
The software then saves all the information in a "*.diag" file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.