− | + | === Project Managment === | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | This section let you change how the project information are handled by the software | |
− | + | ||
+ | ; Scanner Project : the path where the software saves all the projects created by the user | ||
+ | ; Implans : the path where the software will search for the implant libraries | ||
+ | ; Usa Numeration Type : if this option is checked, the software will use the Universal Tooth Numbering System | ||
+ | ; Auto Save : if this option is checked, the software will automatically save the project after every main step (Acquisition, Alignment, Mesh Generation) | ||
+ | ; Compressed Projects : if this options is enabled the software will compress the projet data saving up to 70% of the space on the disk. The compressed project can not be loaded by previous version of the software | ||
+ | ; Min RI sample number : the minimum number of points for an acquisition to be valid. Under the threshold, all the acquisitions will be automatically discarded | ||
+ | |||
+ | === Multi Die Parameter === | ||
+ | |||
+ | The parameters in this section handle the Multi-Die support. Is suggested not to modify these parameters but to use the specific multi-die calibration instead. | ||
+ | |||
+ | === Wizard Option === | ||
+ | |||
+ | This section let you change the workflow of the Step-By-Step wizard | ||
− | + | ; Check Articulator Alignment : if this option is checked, the software will show the result of the alignment with the articulation during the Step-By-Step Wizard | |
+ | ; Show Parallel Mesh Generation : if this option is checked, the software will show a function to generate the Meshes during the next scanning step and not at the specific Mesh Generation Step. This function is longer a valid option to speed up the project | ||
+ | ; Stumps Manual Cut : if this option is checked, the software will show the user an additional Manual Cut step for every stump in the project | ||
− | + | === Wizard Auto Cut === | |
− | |||
− | + | This section let you enable and disable the automatic cut of duplicated surface for the entire Step-By-Step wizard or only for some elements | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | <!--T: | + | <!--T:7--> |
− | {{Screenshot| | + | {{Screenshot|Dental_2_5_options_dental_general.jpg}} |
− | == | + | == Exporters == |
− | + | In this page the user can add, rename, remove [[Man_DataExport#Automatic_Export|exporters profiles]]. | |
− | |||
− | |||
− | + | {{Screenshot|Options-exporters.jpg}} | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</translate> | </translate> | ||
{{Navigation|Dental_Options_Global|Dental_Options_Interactor}} | {{Navigation|Dental_Options_Global|Dental_Options_Interactor}} |
Revision as of 11:24, 27 November 2015
Contents
Dental
This options section provides information on how the Step-By-Step wizard works, how to integrate the software with other CAD systems and how to configure the automatic export system for the structured projects.
There are 2 sub-categories:
General
In the General Page there are:
Project Managment
This section let you change how the project information are handled by the software
- Scanner Project
- the path where the software saves all the projects created by the user
- Implans
- the path where the software will search for the implant libraries
- Usa Numeration Type
- if this option is checked, the software will use the Universal Tooth Numbering System
- Auto Save
- if this option is checked, the software will automatically save the project after every main step (Acquisition, Alignment, Mesh Generation)
- Compressed Projects
- if this options is enabled the software will compress the projet data saving up to 70% of the space on the disk. The compressed project can not be loaded by previous version of the software
- Min RI sample number
- the minimum number of points for an acquisition to be valid. Under the threshold, all the acquisitions will be automatically discarded
Multi Die Parameter
The parameters in this section handle the Multi-Die support. Is suggested not to modify these parameters but to use the specific multi-die calibration instead.
Wizard Option
This section let you change the workflow of the Step-By-Step wizard
- Check Articulator Alignment
- if this option is checked, the software will show the result of the alignment with the articulation during the Step-By-Step Wizard
- Show Parallel Mesh Generation
- if this option is checked, the software will show a function to generate the Meshes during the next scanning step and not at the specific Mesh Generation Step. This function is longer a valid option to speed up the project
- Stumps Manual Cut
- if this option is checked, the software will show the user an additional Manual Cut step for every stump in the project
Wizard Auto Cut
This section let you enable and disable the automatic cut of duplicated surface for the entire Step-By-Step wizard or only for some elements
Exporters
In this page the user can add, rename, remove exporters profiles.