Difference between revisions of "Nobel Biocare Bränemark®"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(Created page with "We have three sizes. * OPT-2101 - ∅ Np * OPT-2102 - ∅ Rp * OPT-2103 - ∅ Wp We have the following options in the Implant Library: * OPT-2101 * OPT-2101 E * OPT-2101 E...")
 
(Undo revision 9016 by L.Pizzoli (talk))
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
=Nobel Biocare Bränemark®=
 
We have three sizes.
 
We have three sizes.
  
Line 7: Line 8:
 
We have the following options in the Implant Library:
 
We have the following options in the Implant Library:
  
* OPT-2101
+
==OPT-2101==
 
* OPT-2101 E
 
* OPT-2101 E
 
* OPT-2101 E ZR
 
* OPT-2101 E ZR
Line 15: Line 16:
 
* OPT-2101 NON E ZR TYPE B
 
* OPT-2101 NON E ZR TYPE B
  
* OPT-2102
+
==OPT-2102==
 
* OPT-2102 E
 
* OPT-2102 E
 
* OPT-2102 E ZR
 
* OPT-2102 E ZR
Line 23: Line 24:
 
* OPT-2102 NON E ZR TYPE B
 
* OPT-2102 NON E ZR TYPE B
  
* OPT-2103
+
==OPT-2103==
 
* OPT-2103 E
 
* OPT-2103 E
 
* OPT-2103 E ZR
 
* OPT-2103 E ZR
Line 31: Line 32:
 
* OPT-2103 NON E ZR TYPE B
 
* OPT-2103 NON E ZR TYPE B
  
 +
=Clarifying Notes=
 +
;E = Engaging.
 +
;NON E = Non Engaging.
 +
;ZR = When we want to use the library to produce zirconium structures.
 +
;TYPE A = the connection is normal and it is advised to use in  cases with good parallelism.
 +
;TYPE B = the connection is more broad and it is advisable to use in cases of bad parallelism.
 +
It is advisable to test these options in order to choose the most appropriate to each one when needed.
  
Clarifying Notes
 
 
[[File:OPT-2100-TYPEA.jpg|left|frame|Type A]]
 
[[File:OPT-2100-TYPEA.jpg|left|frame|Type A]]
 
[[File:OPT-2100-TYPEB.jpg|left|frame|Type B]]
 
[[File:OPT-2100-TYPEB.jpg|left|frame|Type B]]
;''E'' = Engaging.
 
;''NON E'' = Non Engaging.
 
;''ZE'' = When we want to use the library to produce zirconium structures.
 
;''TYPE A'' = the connection is normal and it is advised to use in  cases with good parallelism.
 
;''TYPE B'' = the connection is more broad and it is advisable to use in cases of bad parallelism.
 
It is advisable to test these options in order to choose the most appropriate to each one when needed.
 

Latest revision as of 14:38, 9 December 2015

Nobel Biocare Bränemark®

We have three sizes.

  • OPT-2101 - ∅ Np
  • OPT-2102 - ∅ Rp
  • OPT-2103 - ∅ Wp

We have the following options in the Implant Library:

OPT-2101

  • OPT-2101 E
  • OPT-2101 E ZR
  • OPT-2101 NON E TYPE A
  • OPT-2101 NON E ZR TYPE A
  • OPT-2101 NON E TYPE B
  • OPT-2101 NON E ZR TYPE B

OPT-2102

  • OPT-2102 E
  • OPT-2102 E ZR
  • OPT-2102 NON E TYPE A
  • OPT-2102 NON E ZR TYPE A
  • OPT-2102 NON E TYPE B
  • OPT-2102 NON E ZR TYPE B

OPT-2103

  • OPT-2103 E
  • OPT-2103 E ZR
  • OPT-2103 NON E TYPE A
  • OPT-2103 NON E ZR TYPE A
  • OPT-2103 NON E TYPE B
  • OPT-2103 NON E ZR TYPE B

Clarifying Notes

E = Engaging.
NON E = Non Engaging.
ZR = When we want to use the library to produce zirconium structures.
TYPE A = the connection is normal and it is advised to use in cases with good parallelism.
TYPE B = the connection is more broad and it is advisable to use in cases of bad parallelism.

It is advisable to test these options in order to choose the most appropriate to each one when needed.