Difference between revisions of "Dentsply Friadent Xive®"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(Created page with "We have four sizes. * OPT-2201 - ∅ 3,4 * OPT-2202 - ∅ 3,8 * OPT-2203 - ∅ 4,5 * OPT-2204 - ∅ 5,5 We have the following options in the Implant Library: * OPT-2201 * O...")
 
(Undo revision 9020 by L.Pizzoli (talk))
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
=Dentsply Friadent Xive®=
 
We have four sizes.
 
We have four sizes.
  
Line 8: Line 9:
 
We have the following options in the Implant Library:
 
We have the following options in the Implant Library:
  
* OPT-2201
+
== OPT-2201 ==
 
* OPT-2201 E
 
* OPT-2201 E
 
* OPT-2201 E ZR
 
* OPT-2201 E ZR
Line 16: Line 17:
 
* OPT-2201 NON E ZR TYPE B
 
* OPT-2201 NON E ZR TYPE B
  
* OPT-2202
+
==OPT-2202==
 
* OPT-2202 E
 
* OPT-2202 E
 
* OPT-2202 E ZR
 
* OPT-2202 E ZR
Line 24: Line 25:
 
* OPT-2202 NON E ZR TYPE B
 
* OPT-2202 NON E ZR TYPE B
  
* OPT-2203
+
==OPT-2203==
 
* OPT-2203 E
 
* OPT-2203 E
 
* OPT-2203 E ZR
 
* OPT-2203 E ZR
Line 32: Line 33:
 
* OPT-2203 NON E ZR TYPE B
 
* OPT-2203 NON E ZR TYPE B
  
* OPT-2204
+
==OPT-2204==
 
* OPT-2204 E
 
* OPT-2204 E
 
* OPT-2204 E ZR
 
* OPT-2204 E ZR
Line 40: Line 41:
 
* OPT-2204 NON E ZR TYPE B
 
* OPT-2204 NON E ZR TYPE B
  
Clarifying Notes
+
=Clarifying Notes=
 +
;E = Engaging.
 +
;NON E = Non Engaging.
 +
;ZR = When we want to use the library to produce zirconium structures.
 +
;TYPE A = the connection is deeper and it is advised to use in  cases with good parallelism. (Picture 1.)
 +
;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. (Picture 2.)
 +
It is advisable to test these options in order to choose the most appropriate to each one when needed.
 +
 
 
[[File:OPT-2200-TYPEA.jpg|left|frame|Type A]]
 
[[File:OPT-2200-TYPEA.jpg|left|frame|Type A]]
 
[[File:OPT-2200-TYPEB.jpg|left|frame|Type B]]
 
[[File:OPT-2200-TYPEB.jpg|left|frame|Type B]]
;''E'' = Engaging.
 
;''NON E'' = Non Engaging.
 
;''ZR'' = When we want to use the library to produce zirconium structures.
 
;''TYPE A'' = the connection is deeper and it is advised to use in  cases with good parallelism. (Picture 1.)
 
;''TYPE B'' = the connection is shorter and it is advisable to use in cases of bad parallelism. (Picture 2.)
 
It is advisable to test these options in order to choose the most appropriate to each one when needed.
 

Latest revision as of 14:38, 9 December 2015

Dentsply Friadent Xive®

We have four sizes.

  • OPT-2201 - ∅ 3,4
  • OPT-2202 - ∅ 3,8
  • OPT-2203 - ∅ 4,5
  • OPT-2204 - ∅ 5,5

We have the following options in the Implant Library:

OPT-2201

  • OPT-2201 E
  • OPT-2201 E ZR
  • OPT-2201 NON E TYPE A
  • OPT-2201 NON E ZR TYPE A
  • OPT-2201 NON E TYPE B
  • OPT-2201 NON E ZR TYPE B

OPT-2202

  • OPT-2202 E
  • OPT-2202 E ZR
  • OPT-2202 NON E TYPE A
  • OPT-2202 NON E ZR TYPE A
  • OPT-2202 NON E TYPE B
  • OPT-2202 NON E ZR TYPE B

OPT-2203

  • OPT-2203 E
  • OPT-2203 E ZR
  • OPT-2203 NON E TYPE A
  • OPT-2203 NON E ZR TYPE A
  • OPT-2203 NON E TYPE B
  • OPT-2203 NON E ZR TYPE B

OPT-2204

  • OPT-2204 E
  • OPT-2204 E ZR
  • OPT-2204 NON E TYPE A
  • OPT-2204 NON E ZR TYPE A
  • OPT-2204 NON E TYPE B
  • OPT-2204 NON E ZR TYPE B

Clarifying Notes

E = Engaging.
NON E = Non Engaging.
ZR = When we want to use the library to produce zirconium structures.
TYPE A = the connection is deeper and it is advised to use in cases with good parallelism. (Picture 1.)
TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. (Picture 2.)

It is advisable to test these options in order to choose the most appropriate to each one when needed.

Type A
Type B