This options section provide the minimum information for the scanner connection. OpticalRevEng Dental can works with many scanner configured at the same time, but only one scanner can be the active one. The current active scanner is selected in the configured scanner list in the drop down menu at the top of the dialog.
+
<!--T:5-->
 +
This options section provides the minimum information for the scanner connection. OpticalRevEng Dental is configured to work with many scanners, however only one scanner at a time can be active. The current active scanner is selected in the configured scanner list in the drop down menu at the top of the dialog.
  
 
<!--T:2-->
 
<!--T:2-->
 
There are two ways to add a scanner configuration:
 
There are two ways to add a scanner configuration:
  
* '''Import a new configuration file''' button : Opens a '''Open File Dialog'' to find and load a configuration file from the disk
+
<!--T:6-->
* '''Load configuration file from Scanner''' button : Try to downloads the configuration from the scanner memory (Available only on scanner from 2015 and later)
+
* '''Import a new configuration file''' : opens an '''Open File Dialog''' to find and load a configuration file from the disk
 +
* '''Load configuration file from Scanner''' : downloads the configuration file from the scanner's memory (only available from the 2015 scanners' version)
  
 
<!--T:3-->
 
<!--T:3-->
After the scanner configuration there are 3 global options:
+
After the scanner configuration, there are 3 global options:
  
* '''GPU Enabled''' : The software to use the GPU to speed up the Mesh Generation if this option is enabled.
+
<!--T:7-->
* '''Do Home Search at start''' : The scanner will search for the movement system zero position every time the software starts if this option is enabled.
+
* '''Turn Off Projector at Close''' : this option configures the behaviour of the projector any time the software is closed:
* '''Turn Off Projector at Close''' : This options configure what the software will do with the projector when it's closed:
+
** '''Always''' : the projector will be turned off every time the software is closed
** '''Always''' : The projector is turned off every time the software is closed without asking anything
+
** '''Never''' : the projector will be left on every time the software is closed (it will turn off automatically after a few minutes)
** '''Never''' : The projector is left on every time the software is closed without asking anything (It'll turn off automatically after some time)
+
** '''Ask''' :  when the software is closed, it will ask the user whether the projector must be switched off or not
** '''Ask''' :  When the software close it'll ask the user what to do
+
* '''Do Home Search at start''' : if this option is enabled, the scanner will look for the movement system's zero position every time it is launched.
  
 
<!--T:4-->
 
<!--T:4-->
[[File:Dental 2 5 options global.jpg|center]]
+
{{Screenshot|Dental _3 _5 _options global.PNG}}
 +
 
 
</translate>
 
</translate>
 +
{{Navigation|Dental_Options|Dental_Options_Dental}}

Latest revision as of 10:42, 9 January 2017


Global

This options section provides the minimum information for the scanner connection. OpticalRevEng Dental is configured to work with many scanners, however only one scanner at a time can be active. The current active scanner is selected in the configured scanner list in the drop down menu at the top of the dialog.

There are two ways to add a scanner configuration:

  • Import a new configuration file : opens an Open File Dialog to find and load a configuration file from the disk
  • Load configuration file from Scanner : downloads the configuration file from the scanner's memory (only available from the 2015 scanners' version)

After the scanner configuration, there are 3 global options:

  • Turn Off Projector at Close : this option configures the behaviour of the projector any time the software is closed:
    • Always : the projector will be turned off every time the software is closed
    • Never : the projector will be left on every time the software is closed (it will turn off automatically after a few minutes)
    • Ask : when the software is closed, it will ask the user whether the projector must be switched off or not
  • Do Home Search at start : if this option is enabled, the scanner will look for the movement system's zero position every time it is launched.

Dental 3 5 options global.PNG

Dental 2 5 wiz prev.png Homebutton.png Dental 2 5 wiz next.png