Nobel Biocare Active®

From Open Tech Dental Wiki 4.0
Revision as of 06:51, 28 July 2015 by Admin (talk | contribs) (Created page with "We have two connection. * OPT-3101 - ∅ Np * OPT-3102 - ∅ Rp We have the following options in the Implant Library: =OPT-3101= *OPT-3101 E *OPT-3101 E ZR *OPT-3101 E S *O...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

We have two connection.

  • OPT-3101 - ∅ Np
  • OPT-3102 - ∅ Rp

We have the following options in the Implant Library:

OPT-3101

  • OPT-3101 E
  • OPT-3101 E ZR
  • OPT-3101 E S
  • OPT-3101 E S ZR
  • OPT-3101 NON E
  • OPT-3101 NON E S
  • OPT-3101 NON E ZR
  • OPT-3101 NON E S ZR


OPT-3102

  • OPT-3102 E
  • OPT-3102 E ZR
  • OPT-3102 E S
  • OPT-3102 E S ZR
  • OPT-3102 E V S
  • OPT-3102 E S V ZR
  • OPT-3102 NON E TYPE A
  • OPT-3102 NON E ZR TYPE A
  • OPT-3102 NON E S TYPE A
  • OPT-3102 NON E S ZR TYPE A
  • OPT-3102 NON E V S TYPE A
  • OPT-3102 NON E V S ZR TYPE A

Clarifying Notes

OPT-3100-img1.jpg
OPT-3100-img2.jpg
E = Engaging.
NON E = Non Engaging.
ZR = When we want to use the library to produce zirconium structures
TYPE A = the connection is normal and it is advised to use in cases with good parallelism. (Picture 1 and 4.)
TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism, is coming soon.
S = Short. In this connection the cone will be less visible. Will be closer to the implant. (Picture 2 and 5.)
V S = Very Short. In this connection the cone will be much less visible. Will be much closer to the implant. (Picture 3 and 6.)

It is advisable to test these options in order to choose the most appropriate to each one when needed.