Difference between revisions of "Straumann Tissue Level®"
Line 20: | Line 20: | ||
*OPT-7102 NON E TYPE A | *OPT-7102 NON E TYPE A | ||
*OPT-7102 NON E ZR TYPE A | *OPT-7102 NON E ZR TYPE A | ||
+ | *OPT-7102 NON E TYPE B | ||
+ | *OPT-7102 NON E ZR TYPE B | ||
+ | *OPT-7102 NON E TYPE C | ||
+ | *OPT-7102 NON E ZR TYPE C | ||
*OPT-7102 E deep | *OPT-7102 E deep | ||
*OPT-7102 E ZR deep | *OPT-7102 E ZR deep | ||
*OPT-7102 NON E TYPE A deep | *OPT-7102 NON E TYPE A deep | ||
+ | *OPT-7102 NON E TYPE B deep | ||
==OPT-7103== | ==OPT-7103== | ||
Line 46: | Line 51: | ||
;E = Engaging. | ;E = Engaging. | ||
;NON E = Non Engaging. | ;NON E = Non Engaging. | ||
− | ;TYPE A = | + | ;TYPE A = the connection is deeper and it is advised to use in cases with good parallelism. |
+ | ;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. | ||
+ | ;TYPE C = the connection is very short and it is advisable to use in cases of very bad parallelism. | ||
;deep = that the design is ready to use the screw **"Basal"**. | ;deep = that the design is ready to use the screw **"Basal"**. | ||
;ZR = the connection is for zirconium structures | ;ZR = the connection is for zirconium structures | ||
It is advisable to test these options in order to choose the most appropriate to each one when needed. | It is advisable to test these options in order to choose the most appropriate to each one when needed. |
Revision as of 14:44, 9 December 2015
Contents
Straumann Tissue Level®
We have five sizes.
- OPT-7101 - ∅ 3,5
- OPT-7102 - ∅ 4,8
- OPT-7103 - ∅ 4,8 Synocta
- OPT-7104 - ∅ 6,5
- OPT-7105 - ∅ 6,5 Synocta
We have the following options in the Implant Library:
OPT-7101
- OPT-7101 E
- OPT-7101 NON E
OPT-7102
- OPT-7102 E
- OPT-7102 E ZR
- OPT-7102 NON E TYPE A
- OPT-7102 NON E ZR TYPE A
- OPT-7102 NON E TYPE B
- OPT-7102 NON E ZR TYPE B
- OPT-7102 NON E TYPE C
- OPT-7102 NON E ZR TYPE C
- OPT-7102 E deep
- OPT-7102 E ZR deep
- OPT-7102 NON E TYPE A deep
- OPT-7102 NON E TYPE B deep
OPT-7103
- OPT-7103 NON E
- OPT-7103 NON E ZR
- OPT-7103 E
- OPT-7103 E ZR
OPT-7104
- OPT-7104 E
- OPT-7104 E ZR
- OPT-7104 NON E TYPE A
- OPT-7104 NON E ZR TYPE A
OPT-7105
- OPT-7105 E
- OPT-7105 E ZR
- OPT-7105 NON E TYPE A
- OPT-7105 NON E ZR TYPE A
Clarifying Notes
- E = Engaging.
- NON E = Non Engaging.
- TYPE A = the connection is deeper and it is advised to use in cases with good parallelism.
- TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
- TYPE C = the connection is very short and it is advisable to use in cases of very bad parallelism.
- deep = that the design is ready to use the screw **"Basal"**.
- ZR = the connection is for zirconium structures
It is advisable to test these options in order to choose the most appropriate to each one when needed.