Difference between revisions of "AstraTech®"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(Created page with "We have five connection. * OPT-1201 - ∅ 3.0 * OPT-1202 - ∅ 3,5/4,0 * OPT-1203 - ∅ 4,5/5,0 * OPT-1204 - ∅ Conic 20º * OPT-1205 - ∅ Conic 45º We have the following...")
 
 
Line 1: Line 1:
 +
= AstraTech® =
 
We have five connection.
 
We have five connection.
  
Line 9: Line 10:
 
We have the following Options in the Implant Library:
 
We have the following Options in the Implant Library:
  
* OPT-1201
+
== OPT-1201 ==
 
* OPT-1201 E
 
* OPT-1201 E
 
* OPT-1201 NON E
 
* OPT-1201 NON E
  
* OPT-1202
+
==  OPT-1202 ==
 
* OPT-1202 E
 
* OPT-1202 E
 
* OPT-1202 E S
 
* OPT-1202 E S
Line 28: Line 29:
  
  
* OPT-1203
+
== OPT-1203 ==
 
* OPT-1203 E
 
* OPT-1203 E
 
* OPT-1203 E S
 
* OPT-1203 E S
Line 39: Line 40:
 
* OPT-1203 NON E S ZR
 
* OPT-1203 NON E S ZR
  
 
+
== OPT-1204 ==
* OPT-1204
 
 
* OPT-1204 NON E
 
* OPT-1204 NON E
  
* OPT-1205
+
== OPT-1205 ==
 
* OPT-1205 NON E
 
* OPT-1205 NON E
  
 +
= Clarifying Notes =
 +
;E = Engaging.
 +
;NON E = Non Engaging.
 +
;S = Short. In this connection the cone will be less visible. Will be closer to the implant.(Picture 1.)
 +
;V S = Very Short. In this connection the cone will be much less visible. Will be much closer to the implant.(Picture 2.)
 +
;ZR = To be used with zirconium structures
 +
It is advisable to test these Options in order to choose the most appropriate to each one when needed.
  
Clarifying Notes
 
 
[[File:OPT-1200-S.jpg|left|frame|S]]
 
[[File:OPT-1200-S.jpg|left|frame|S]]
 
[[File:OPT-1200-VS.jpg|left|frame|VS]]
 
[[File:OPT-1200-VS.jpg|left|frame|VS]]
;''E'' = Engaging.
 
;''NON E'' = Non Engaging.
 
;''S'' = Short. In this connection the cone will be less visible. Will be closer to the implant.(Picture 1.)
 
;''V S'' = Very Short. In this connection the cone will be much less visible. Will be much closer to the implant.(Picture 2.)
 
;''ZR'' = To be used with zirconium structures
 
It is advisable to test these Options in order to choose the most appropriate to each one when needed.
 

Latest revision as of 08:53, 28 July 2015

AstraTech®

We have five connection.

  • OPT-1201 - ∅ 3.0
  • OPT-1202 - ∅ 3,5/4,0
  • OPT-1203 - ∅ 4,5/5,0
  • OPT-1204 - ∅ Conic 20º
  • OPT-1205 - ∅ Conic 45º

We have the following Options in the Implant Library:

OPT-1201

  • OPT-1201 E
  • OPT-1201 NON E

OPT-1202

  • OPT-1202 E
  • OPT-1202 E S
  • OPT-1202 E V S
  • OPT-1202 E ZR
  • OPT-1202 E S ZR
  • OPT-1202 E S V ZR
  • OPT-1202 NON E
  • OPT-1202 NON E S
  • OPT-1202 NON E V S
  • OPT-1202 NON E ZR
  • OPT-1202 NON E S ZR
  • OPT-1202 NON E V S ZR


OPT-1203

  • OPT-1203 E
  • OPT-1203 E S
  • OPT-1203 E ZR
  • OPT-1203 E S ZR
  • OPT-1203 NON E
  • OPT-1203 NON E S
  • OPT-1203 NON E ZR
  • OPT-1203 NON E ZR
  • OPT-1203 NON E S ZR

OPT-1204

  • OPT-1204 NON E

OPT-1205

  • OPT-1205 NON E

Clarifying Notes

E = Engaging.
NON E = Non Engaging.
S = Short. In this connection the cone will be less visible. Will be closer to the implant.(Picture 1.)
V S = Very Short. In this connection the cone will be much less visible. Will be much closer to the implant.(Picture 2.)
ZR = To be used with zirconium structures

It is advisable to test these Options in order to choose the most appropriate to each one when needed.

S
VS