Difference between revisions of "Nobel Biocare Replace Select®"
Line 1: | Line 1: | ||
+ | = Nobel_Biocare_Replace_Select® = | ||
We have four sizes. | We have four sizes. | ||
Line 6: | Line 7: | ||
* OPT-1104 - 6.0 | * OPT-1104 - 6.0 | ||
− | We have the following | + | We have the following options in the Implant Library: |
− | + | ==OPT-1101 == | |
* OPT-1101 E | * OPT-1101 E | ||
* OPT-1101 E ZR | * OPT-1101 E ZR | ||
Line 16: | Line 17: | ||
* OPT-1101 NON E ZR TYPE B | * OPT-1101 NON E ZR TYPE B | ||
− | + | == OPT-1102 == | |
* OPT-1102 E | * OPT-1102 E | ||
* OPT-1102 E ZR | * OPT-1102 E ZR | ||
Line 24: | Line 25: | ||
* OPT-1102 NON E ZR TYPE B | * OPT-1102 NON E ZR TYPE B | ||
− | + | == OPT-1103 == | |
* OPT-1103 E | * OPT-1103 E | ||
* OPT-1103 E ZR | * OPT-1103 E ZR | ||
Line 32: | Line 33: | ||
* OPT-1103 NON E ZR TYPE B | * OPT-1103 NON E ZR TYPE B | ||
− | + | == OPT-1104 == | |
* OPT-1104 E | * OPT-1104 E | ||
* OPT-1104 NON E | * OPT-1104 NON E | ||
+ | |||
+ | = Clarifying Notes = | ||
+ | |||
+ | ;'E' = Engaging. | ||
+ | ;NON E = Non Engaging. | ||
+ | ;TYPE A = the connection is deeper and it is advised to use in cases with good parallelism. | ||
+ | ;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. | ||
+ | ;ZR = the connection is for zirconium structures | ||
[[File:OPT-1100-small.jpg|frame|left|Type A]] | [[File:OPT-1100-small.jpg|frame|left|Type A]] | ||
[[File:OPT-1100-large.jpg|frame|left|Type B]] | [[File:OPT-1100-large.jpg|frame|left|Type B]] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Revision as of 08:50, 28 July 2015
Contents
Nobel_Biocare_Replace_Select®
We have four sizes.
- OPT-1101 - NP
- OPT-1102 - RP
- OPT-1103 - WP
- OPT-1104 - 6.0
We have the following options in the Implant Library:
OPT-1101
- OPT-1101 E
- OPT-1101 E ZR
- OPT-1101 NON E TYPE A
- OPT-1101 NON E ZR TYPE A
- OPT-1101 NON E TYPE B
- OPT-1101 NON E ZR TYPE B
OPT-1102
- OPT-1102 E
- OPT-1102 E ZR
- OPT-1102 NON E TYPE A
- OPT-1102 NON E ZR TYPE A
- OPT-1102 NON E TYPE B
- OPT-1102 NON E ZR TYPE B
OPT-1103
- OPT-1103 E
- OPT-1103 E ZR
- OPT-1103 NON E TYPE A
- OPT-1103 NON E ZR TYPE A
- OPT-1103 NON E TYPE B
- OPT-1103 NON E ZR TYPE B
OPT-1104
- OPT-1104 E
- OPT-1104 NON E
Clarifying Notes
- 'E' = Engaging.
- NON E = Non Engaging.
- TYPE A = the connection is deeper and it is advised to use in cases with good parallelism.
- TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
- ZR = the connection is for zirconium structures