*OPT-5101 NON E TYPE A
 
*OPT-5101 NON E TYPE A
 
*OPT-5101 NON E ZR TYPE A
 
*OPT-5101 NON E ZR TYPE A
 +
*OPT-5101 NON E TYPE B
 +
*OPT-5101 NON E ZR TYPE B
  
 
==OPT-5102==
 
==OPT-5102==
Line 20: Line 22:
 
*OPT-5102 NON E TYPE A
 
*OPT-5102 NON E TYPE A
 
*OPT-5102 NON E ZR TYPE A
 
*OPT-5102 NON E ZR TYPE A
 +
*OPT-5102 NON E TYPE B
 +
*OPT-5102 NON E ZR TYPE B
  
 
==OPT-5103==
 
==OPT-5103==
Line 26: Line 30:
 
*OPT-5103 NON E TYPE A
 
*OPT-5103 NON E TYPE A
 
*OPT-5103 NON E ZR TYPE A
 
*OPT-5103 NON E ZR TYPE A
 
+
*OPT-5103 NON E TYPE B
 +
*OPT-5103 NON E ZR TYPE B
 
= Clarifying Notes =
 
= Clarifying Notes =
  
 
;E = Engaging.
 
;E = Engaging.
 
;NON E = Non Engaging.
 
;NON E = Non Engaging.
;TYPE A = Normal connection. In the provided library there are also other types of connections (B-C), however we suggest using only Type A.
+
;TYPE A = the connection is deeper and it is advised to use in  cases with good parallelism.
 +
;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.  
 
;ZR = the connection is for zirconium structures
 
;ZR = the connection is for zirconium structures
 
It is advisable to test these options in order to choose the most appropriate to each one when needed.
 
It is advisable to test these options in order to choose the most appropriate to each one when needed.

Latest revision as of 14:42, 9 December 2015

Biomet 3i Certain®

We have three sizes.

  • OPT-5101 - ∅ 3,4
  • OPT-5102 - ∅ 4,1
  • OPT-5103 - ∅ 5,5

We have the following options in the Implant Library:

OPT-5101

  • OPT-5101 E
  • OPT-5101 E ZR
  • OPT-5101 NON E TYPE A
  • OPT-5101 NON E ZR TYPE A
  • OPT-5101 NON E TYPE B
  • OPT-5101 NON E ZR TYPE B

OPT-5102

  • OPT-5102 E
  • OPT-5102 E ZR
  • OPT-5102 NON E TYPE A
  • OPT-5102 NON E ZR TYPE A
  • OPT-5102 NON E TYPE B
  • OPT-5102 NON E ZR TYPE B

OPT-5103

  • OPT-5103 E
  • OPT-5103 E ZR
  • OPT-5103 NON E TYPE A
  • OPT-5103 NON E ZR TYPE A
  • OPT-5103 NON E TYPE B
  • OPT-5103 NON E ZR TYPE B

Clarifying Notes

E = Engaging.
NON E = Non Engaging.
TYPE A = the connection is deeper and it is advised to use in cases with good parallelism.
TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
ZR = the connection is for zirconium structures

It is advisable to test these options in order to choose the most appropriate to each one when needed.

OPT-5100-img1.jpg
OPT-5100-img2.jpg