Difference between revisions of "Nobel Biocare Replace Select®"
Line 1: | Line 1: | ||
= Nobel_Biocare_Replace_Select® = | = Nobel_Biocare_Replace_Select® = | ||
− | |||
We have four sizes. | We have four sizes. | ||
Line 14: | Line 13: | ||
* OPT-1101 E ZR | * OPT-1101 E ZR | ||
* OPT-1101 NON E TYPE A | * OPT-1101 NON E TYPE A | ||
+ | * OPT-1101 NON E ZR TYPE A | ||
+ | * OPT-1101 NON E TYPE B | ||
+ | * OPT-1101 NON E ZR TYPE B | ||
== OPT-1102 == | == OPT-1102 == | ||
Line 20: | Line 22: | ||
* OPT-1102 NON E TYPE A | * OPT-1102 NON E TYPE A | ||
* OPT-1102 NON E ZR TYPE A | * OPT-1102 NON E ZR TYPE A | ||
+ | * OPT-1102 NON E TYPE B | ||
+ | * OPT-1102 NON E ZR TYPE B | ||
== OPT-1103 == | == OPT-1103 == | ||
Line 26: | Line 30: | ||
* OPT-1103 NON E TYPE A | * OPT-1103 NON E TYPE A | ||
* OPT-1103 NON E ZR TYPE A | * OPT-1103 NON E ZR TYPE A | ||
+ | * OPT-1103 NON E TYPE B | ||
+ | * OPT-1103 NON E ZR TYPE B | ||
== OPT-1104 == | == OPT-1104 == | ||
Line 35: | Line 41: | ||
;'E' = Engaging. | ;'E' = Engaging. | ||
;NON E = Non Engaging. | ;NON E = Non Engaging. | ||
− | ;TYPE A = | + | ;TYPE A = the connection is deeper and it is advised to use in cases with good parallelism. |
+ | ;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. | ||
;ZR = the connection is for zirconium structures. | ;ZR = the connection is for zirconium structures. | ||
[[File:OPT-1100-small.jpg|frame|left|Type A]] | [[File:OPT-1100-small.jpg|frame|left|Type A]] | ||
+ | [[File:OPT-1100-large.jpg|frame|left|Type B]] |
Latest revision as of 14:36, 9 December 2015
Contents
Nobel_Biocare_Replace_Select®
We have four sizes.
- OPT-1101 - NP
- OPT-1102 - RP
- OPT-1103 - WP
- OPT-1104 - 6.0
We have the following options in the Implant Library:
OPT-1101
- OPT-1101 E
- OPT-1101 E ZR
- OPT-1101 NON E TYPE A
- OPT-1101 NON E ZR TYPE A
- OPT-1101 NON E TYPE B
- OPT-1101 NON E ZR TYPE B
OPT-1102
- OPT-1102 E
- OPT-1102 E ZR
- OPT-1102 NON E TYPE A
- OPT-1102 NON E ZR TYPE A
- OPT-1102 NON E TYPE B
- OPT-1102 NON E ZR TYPE B
OPT-1103
- OPT-1103 E
- OPT-1103 E ZR
- OPT-1103 NON E TYPE A
- OPT-1103 NON E ZR TYPE A
- OPT-1103 NON E TYPE B
- OPT-1103 NON E ZR TYPE B
OPT-1104
- OPT-1104 E
- OPT-1104 NON E
Clarifying Notes
- 'E' = Engaging.
- NON E = Non Engaging.
- TYPE A = the connection is deeper and it is advised to use in cases with good parallelism.
- TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
- ZR = the connection is for zirconium structures.