Difference between revisions of "Nobel Biocare Replace Select®"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(Undo revision 9011 by L.Pizzoli (talk))
 
Line 1: Line 1:
 
= Nobel_Biocare_Replace_Select® =
 
= Nobel_Biocare_Replace_Select® =
 
 
We have four sizes.
 
We have four sizes.
  
Line 14: Line 13:
 
* OPT-1101 E ZR
 
* OPT-1101 E ZR
 
* OPT-1101 NON E TYPE A
 
* OPT-1101 NON E TYPE A
 +
* OPT-1101 NON E ZR TYPE A
 +
* OPT-1101 NON E TYPE B
 +
* OPT-1101 NON E ZR TYPE B
  
 
== OPT-1102 ==
 
== OPT-1102 ==
Line 20: Line 22:
 
* OPT-1102 NON E TYPE A
 
* OPT-1102 NON E TYPE A
 
* OPT-1102 NON E ZR TYPE A
 
* OPT-1102 NON E ZR TYPE A
 +
* OPT-1102 NON E TYPE B
 +
* OPT-1102 NON E ZR TYPE B
  
 
== OPT-1103 ==
 
== OPT-1103 ==
Line 26: Line 30:
 
* OPT-1103 NON E TYPE A
 
* OPT-1103 NON E TYPE A
 
* OPT-1103 NON E ZR TYPE A
 
* OPT-1103 NON E ZR TYPE A
 +
* OPT-1103 NON E TYPE B
 +
* OPT-1103 NON E ZR TYPE B
  
 
== OPT-1104 ==
 
== OPT-1104 ==
Line 35: Line 41:
 
;'E' = Engaging.
 
;'E' = Engaging.
 
;NON E = Non Engaging.
 
;NON E = Non Engaging.
;TYPE A = In the provided library there are also other types of connections (B-C), however we suggest using only Type A.
+
;TYPE A = the connection is deeper and it is advised to use in  cases with good parallelism.
 +
;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
 
;ZR = the connection is for zirconium structures.
 
;ZR = the connection is for zirconium structures.
  
 
[[File:OPT-1100-small.jpg|frame|left|Type A]]
 
[[File:OPT-1100-small.jpg|frame|left|Type A]]
 +
[[File:OPT-1100-large.jpg|frame|left|Type B]]

Latest revision as of 14:36, 9 December 2015

Nobel_Biocare_Replace_Select®

We have four sizes.

  • OPT-1101 - NP
  • OPT-1102 - RP
  • OPT-1103 - WP
  • OPT-1104 - 6.0

We have the following options in the Implant Library:

OPT-1101

  • OPT-1101 E
  • OPT-1101 E ZR
  • OPT-1101 NON E TYPE A
  • OPT-1101 NON E ZR TYPE A
  • OPT-1101 NON E TYPE B
  • OPT-1101 NON E ZR TYPE B

OPT-1102

  • OPT-1102 E
  • OPT-1102 E ZR
  • OPT-1102 NON E TYPE A
  • OPT-1102 NON E ZR TYPE A
  • OPT-1102 NON E TYPE B
  • OPT-1102 NON E ZR TYPE B

OPT-1103

  • OPT-1103 E
  • OPT-1103 E ZR
  • OPT-1103 NON E TYPE A
  • OPT-1103 NON E ZR TYPE A
  • OPT-1103 NON E TYPE B
  • OPT-1103 NON E ZR TYPE B

OPT-1104

  • OPT-1104 E
  • OPT-1104 NON E

Clarifying Notes

'E' = Engaging.
NON E = Non Engaging.
TYPE A = the connection is deeper and it is advised to use in cases with good parallelism.
TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
ZR = the connection is for zirconium structures.
Type A
Type B