Difference between revisions of "Wiz Acquisition"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
 
(16 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<languages/>
+
{{Language bar}}
{{DISPLAYTITLE:Wizard Acquisition}}
+
{{DISPLAYTITLE:Wizard Acquisition|noerror}}
 
<translate>
 
<translate>
= Wizard Acquisition =
+
= Wizard Acquisition = <!--T:1-->
  
During the Step-By-Step Wizard you'll need to acquire many times. You can acquire single objects, acquire multiple objects in only one scan, reacquire a previously acquire object and you can integrate the acquisitions.
+
<!--T:2-->
 +
During the Step-By-Step Wizard, it is possible to: acquire single objects or multiple objects in one scan, re-acquire a previously acquired object and integrate all these acquisitions.
  
== Single Object ==
+
== Single Object == <!--T:3-->
  
Every time you'll need to acquire something a specific wizard screen will give:
+
<!--T:4-->
 +
Every time an element has to be acquired, a specific wizard screen will show:
  
* The name of the object to acquire
+
<!--T:5-->
* A brief description of exactly what you have to put inside the scanner
+
* The name of the object to be acquired
* A selector for the ''Object Color''
+
* A brief description of what should be scanned
 +
* A selector for the ''Object Colour''
 
* A ''Scan'' Button to start the acquisition
 
* A ''Scan'' Button to start the acquisition
* A ''Integrate'' Button to start the integration of a previously acquired object
+
* An ''Integrate'' Button to start the integration of a previously acquired object
* A ''Already Aligned'' check that tells you if this object was already aligned to the rest of the project
+
* An ''Already Aligned'' check that shows if this object is already aligned to the rest of the project
  
So you just need to:
+
<!--T:6-->
 +
It's very easy to follow the wizard:
  
 +
<!--T:7-->
 
# Read the object description
 
# Read the object description
 
# Put the right object inside the scanner
 
# Put the right object inside the scanner
 
# Click ''Scan''
 
# Click ''Scan''
# If the acquisition is not good enough click ''Scan'' again to start a new acquisition or ''Integrate'' to add further data
+
# If the acquisition is not satisfactory, click again the ''Scan'' button to start a new acquisition, or the ''Integrate'' button to add data
  
[[File:Dental_2_5_wizAcquire.jpg|upright|center]]
+
<!--T:8-->
 +
{{Screenshot|Dental_3_5_wizAcquire.PNG}}
  
=== Copy From Reference ===
+
=== Open Live === <!--T:36-->
  
Sometimes, part of the data needed for one element can be already acquired in another acquisition.  
+
<!--T:37-->
 +
It is possible to open the live view of the cameras, by clickin on the {{Inline button|OpenLive.png}} to see the progress of the scanning in the monitor of the computer.
  
For example the acquisition of the healthy and pontics parts of the jaw is really similar to the reference acquisition of the entire jaw.
+
=== Advanced Parameters === <!--T:32-->
You only need to remove the part of the stumps beacase they'll be acquired in a separate step.
 
  
In theese cases the software will show you an additional button ''Copy From Reference'' that, instead of starting a new acquisition will simply make a copy of the previous one.
+
<!--T:33-->
 +
During the wizard the acquisition strategy is selcted automatically depending on the kind of element to acquire.
  
After the [[Wiz_BaseCut|Base Cut]] step the software will try to remove the duplicated parts from the acquisition automatically.
+
<!--T:34-->
 +
There are some specific cases, however, in which it might be necessary to change the scanning strategy to a non default one. For instance, if the user needs to scan abutments instead of stumps, it would be best to select the specific abutment strategy. Same goes if the user needs to design a veneer: it is not a default strategy for stumps but it can be selected during acquisition.
  
[[File:Dental_2_5_wizHealthyAcquire.jpg|upright|center]]
+
<!--T:35-->
 +
To change strategy, click on the {{Inline button|StartServiceButton.jpg}} button and select it from the drop down menu.
  
= Multi Acquisition =
+
=== Copy From Reference === <!--T:9-->
  
When you have to acquire multiple dies or multiple implants it's better not to do one acquisition for every element.<br />
+
<!--T:10-->
You can freely acquire more than 1 object at the time. <br />
+
Sometimes, one element data has already been scanned during another acquisition.  
You just need to be sure that the objects are not going to hide one between the others during the acquisitions placing them far away or using the Multi-Die support. <br />
 
In theese cases the software will show you a Multi-Acquisition Setup step where yuo can select which object you want to scan togheter.
 
  
This step will show you a list of all the object that you need to acquire and all the object already acquired. You just need to check the object you want to scan togheter and, if you're scanning stumps, check the '''Use Multi-Die support''' options on the bottom if you want to use the Multi-Die holder.
+
<!--T:11-->
 +
{{Important|For example, the acquisition of the healthy and pontics parts of the jaw is similar to the reference acquisition of the entire jaw, except for the stumps, which will be acquired in a separate step.}} 
  
[[File:Dental_2_5_wizMultiStump.jpg|upright|center]]
+
<!--T:12-->
 +
In these cases, the software will show the existing image and automatically remove the parts already scanned in detail. It is always anyways possible to copy the whole image again by clicking ''Copy From Reference'' or to start a new acquisition if the cut copy is not satisfying.
  
=== With Multi-Die ===
+
<!--T:14-->
 +
{{Screenshot|Dental_3_5_wizHealthyAcquire.PNG}}
  
If the Multi-Die is used the software will prepare a specific acquisition for the dies selected with an image to guide you on how to fill the Multi-Die holder.<br />
+
= Multi Acquisition = <!--T:15-->
After the acquisition the software will automatically recognize the single dies and return to the Multi-Acquisition Step to let you acquire additional objects
 
  
[[File:Dental_2_5_wizMultiDieAcquisition.jpg|upright|center]]
+
<!--T:16-->
 +
When acquiring multiple dies or multiple implants, it's better not to carry out a single acquisition for every element.<br />
 +
It is possible to acquire many objects at once. <br />
 +
Just make sure that the objects are completely visible in all their parts and that they are at an adequate distance either on the model holder or on the Multi-Die support. <br />
 +
In these cases, the software will show a Multi-Acquisition Setup step where it is possible to select the objects to be scanned at the same time.
  
=== Without Multi-Die ===
+
<!--T:17-->
 +
This step will show a list of all the objects that have to be scanned together with the already acquired items. Flag the boxes of the objects that have to be scanned together and, when scanning stumps,the flag '''Use Multi-Die support''' option on the bottom of the dialog will be checked by default to allow the use of the Multi-Die holder.
  
If you're not going to use the multi die the software will acquire the objects normally, but later will ask you to manually identify the object one at the time.<br />
+
<!--T:18-->
A specific Wizard Step will tell you what object you need to identify. You need to:
+
{{Screenshot|Dental_2_5_wizMultiStump.jpg}}
  
# Read from the Wizard Page what object you need to select
+
=== With Multi-Die === <!--T:19-->
# Select the specific object using the [[Man_DataEditing|Selection Tool]] you prefer
 
# Click the '''Segment''' button
 
# Click the '''Next''' button
 
  
[[File:Dental_2_5_wizStumpSegment.gif|center]]
+
<!--T:20-->
 +
If the Multi-Die option is selected, the software will set up a specific acquisition for the dies; an image will guide the user in positioning the dies in the Multi-Die holder.<br />
 +
After the acquisition, the software will automatically recognize each single die and return to the Multi-Acquisition Step to allow the acquisition of additional objects.
  
When all the objects are identified you'll return to tue Multi-Acquisition step. When all the object are aquired you can click next without selecting anything to continue with the Step-By-Step Wizard
+
<!--T:21-->
 +
{{Screenshot|Dental_2_5_wizMultiDieAcquisition.jpg}}
  
[[File:Dental_2_5_wizMultiStump-after.jpg|upright|center]]
+
=== Without Multi-Die === <!--T:22-->
  
= Integration =
+
<!--T:23-->
 +
If the Multi-Die gets deselected, the software will acquire the objects and, in the following step, require the user to manually identify each object.<br />
 +
A specific Wizard Step will ask which object has to be identified. The user has to:
  
If after one acquisition you click the '''Integrate''' button you'll enter in the [[Man_Acquisition#Integration|integragion mode]].
+
<!--T:24-->
 +
# Read from the Wizard Page which object has to be selected
 +
# Select the specific object, using a [[Man_DataEditing|Selection Tool]]
 +
# Click the button '''Segment'''
 +
# Click the button '''Next'''
  
= Next =
+
<!--T:25-->
 +
[[File:Dental_2_5_wizStumpSegment.gif]]
 +
 
 +
<!--T:26-->
 +
When the objects are all identified, the software returns to the Multi-Acquisition step. If all the objects have already been aquired, click ''Next'' to continue with the Step-By-Step Wizard
 +
 
 +
<!--T:27-->
 +
{{Screenshot|Dental_2_5_wizMultiStump-after.jpg}}
 +
 
 +
= Integration = <!--T:28-->
 +
 
 +
<!--T:29-->
 +
By clicking the '''Integrate''' button after an acquisition, the [[Man_Acquisition#Integration|Integration mode]] will be launched.
  
After every acquisition you'll arrive at the [[Wiz_BaseCutAndAutoCleaning|Base Cut And Auto Cleaning]] Step.
 
 
</translate>
 
</translate>
 +
{{Navigation|Wiz_Introduction|Wiz_BaseCutAndAutoCleaning}}

Latest revision as of 12:00, 22 June 2016


Wizard Acquisition

During the Step-By-Step Wizard, it is possible to: acquire single objects or multiple objects in one scan, re-acquire a previously acquired object and integrate all these acquisitions.

Single Object

Every time an element has to be acquired, a specific wizard screen will show:

  • The name of the object to be acquired
  • A brief description of what should be scanned
  • A selector for the Object Colour
  • A Scan Button to start the acquisition
  • An Integrate Button to start the integration of a previously acquired object
  • An Already Aligned check that shows if this object is already aligned to the rest of the project

It's very easy to follow the wizard:

  1. Read the object description
  2. Put the right object inside the scanner
  3. Click Scan
  4. If the acquisition is not satisfactory, click again the Scan button to start a new acquisition, or the Integrate button to add data

Dental 3 5 wizAcquire.PNG

Open Live

It is possible to open the live view of the cameras, by clickin on the OpenLive.png to see the progress of the scanning in the monitor of the computer.

Advanced Parameters

During the wizard the acquisition strategy is selcted automatically depending on the kind of element to acquire.

There are some specific cases, however, in which it might be necessary to change the scanning strategy to a non default one. For instance, if the user needs to scan abutments instead of stumps, it would be best to select the specific abutment strategy. Same goes if the user needs to design a veneer: it is not a default strategy for stumps but it can be selected during acquisition.

To change strategy, click on the StartServiceButton.jpg button and select it from the drop down menu.

Copy From Reference

Sometimes, one element data has already been scanned during another acquisition.

For example, the acquisition of the healthy and pontics parts of the jaw is similar to the reference acquisition of the entire jaw, except for the stumps, which will be acquired in a separate step.

In these cases, the software will show the existing image and automatically remove the parts already scanned in detail. It is always anyways possible to copy the whole image again by clicking Copy From Reference or to start a new acquisition if the cut copy is not satisfying.

Dental 3 5 wizHealthyAcquire.PNG

Multi Acquisition

When acquiring multiple dies or multiple implants, it's better not to carry out a single acquisition for every element.
It is possible to acquire many objects at once.
Just make sure that the objects are completely visible in all their parts and that they are at an adequate distance either on the model holder or on the Multi-Die support.
In these cases, the software will show a Multi-Acquisition Setup step where it is possible to select the objects to be scanned at the same time.

This step will show a list of all the objects that have to be scanned together with the already acquired items. Flag the boxes of the objects that have to be scanned together and, when scanning stumps,the flag Use Multi-Die support option on the bottom of the dialog will be checked by default to allow the use of the Multi-Die holder.

Dental 2 5 wizMultiStump.jpg

With Multi-Die

If the Multi-Die option is selected, the software will set up a specific acquisition for the dies; an image will guide the user in positioning the dies in the Multi-Die holder.
After the acquisition, the software will automatically recognize each single die and return to the Multi-Acquisition Step to allow the acquisition of additional objects.

Dental 2 5 wizMultiDieAcquisition.jpg

Without Multi-Die

If the Multi-Die gets deselected, the software will acquire the objects and, in the following step, require the user to manually identify each object.
A specific Wizard Step will ask which object has to be identified. The user has to:

  1. Read from the Wizard Page which object has to be selected
  2. Select the specific object, using a Selection Tool
  3. Click the button Segment
  4. Click the button Next

Dental 2 5 wizStumpSegment.gif

When the objects are all identified, the software returns to the Multi-Acquisition step. If all the objects have already been aquired, click Next to continue with the Step-By-Step Wizard

Dental 2 5 wizMultiStump-after.jpg

Integration

By clicking the Integrate button after an acquisition, the Integration mode will be launched.

Dental 2 5 wiz prev.png Homebutton.png Dental 2 5 wiz next.png