Difference between revisions of "Straumann Tissue Level®"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(OPT-7102 (A h:12.50mm))
 
(3 intermediate revisions by the same user not shown)
Line 20: Line 20:
 
*OPT-7102 NON E TYPE A
 
*OPT-7102 NON E TYPE A
 
*OPT-7102 NON E ZR TYPE A
 
*OPT-7102 NON E ZR TYPE A
*OPT-7102 NON E TYPE B
 
*OPT-7102 NON E ZR TYPE B
 
*OPT-7102 NON E TYPE C
 
*OPT-7102 NON E ZR TYPE C
 
 
*OPT-7102 E deep
 
*OPT-7102 E deep
 
*OPT-7102 E ZR deep
 
*OPT-7102 E ZR deep
 
*OPT-7102 NON E TYPE A deep
 
*OPT-7102 NON E TYPE A deep
*OPT-7102 NON E TYPE B deep
 
  
==OPT-7102 (B h:12mm)==
 
*OPT-7102 E
 
*OPT-7102 E ZR
 
*OPT-7102 NON E TYPE A
 
*OPT-7102 NON E ZR TYPE A
 
*OPT-7102 NON E TYPE B
 
*OPT-7102 NON E ZR TYPE B
 
*OPT-7102 NON E TYPE C
 
*OPT-7102 NON E ZR TYPE C
 
*OPT-7102 E deep
 
*OPT-7102 E ZR deep
 
*OPT-7102 NON E TYPE A deep
 
*OPT-7102 NON E TYPE B deep
 
 
==OPT-7102 (C h:13.10mm)==
 
*OPT-7102 E
 
*OPT-7102 E ZR
 
*OPT-7102 NON E TYPE A
 
*OPT-7102 NON E ZR TYPE A
 
*OPT-7102 NON E TYPE B
 
*OPT-7102 NON E ZR TYPE B
 
*OPT-7102 NON E TYPE C
 
*OPT-7102 NON E ZR TYPE C
 
*OPT-7102 E deep
 
*OPT-7102 E ZR deep
 
*OPT-7102 NON E TYPE A deep
 
*OPT-7102 NON E TYPE B deep
 
  
 
==OPT-7103==
 
==OPT-7103==
Line 79: Line 47:
 
;E = Engaging.
 
;E = Engaging.
 
;NON E = Non Engaging.
 
;NON E = Non Engaging.
;TYPE A = the connection is deeper and it is advised to use in cases with good parallelism.
+
;TYPE A = Normal Connection to be used in all designs.
;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
 
;TYPE C = the connection is very short and it is advisable to use in cases of very bad parallelism.
 
 
;deep = that the design is ready to use the screw **"Basal"**.
 
;deep = that the design is ready to use the screw **"Basal"**.
 
;ZR = the connection is for zirconium structures
 
;ZR = the connection is for zirconium structures
 
It is advisable to test these options in order to choose the most appropriate to each one when needed.
 
It is advisable to test these options in order to choose the most appropriate to each one when needed.

Latest revision as of 16:02, 9 December 2015

Straumann Tissue Level®

We have five sizes.

  • OPT-7101 - ∅ 3,5
  • OPT-7102 - ∅ 4,8
  • OPT-7103 - ∅ 4,8 Synocta
  • OPT-7104 - ∅ 6,5
  • OPT-7105 - ∅ 6,5 Synocta

We have the following options in the Implant Library:

OPT-7101

  • OPT-7101 E
  • OPT-7101 NON E

OPT-7102

  • OPT-7102 E
  • OPT-7102 E ZR
  • OPT-7102 NON E TYPE A
  • OPT-7102 NON E ZR TYPE A
  • OPT-7102 E deep
  • OPT-7102 E ZR deep
  • OPT-7102 NON E TYPE A deep


OPT-7103

  • OPT-7103 NON E
  • OPT-7103 NON E ZR
  • OPT-7103 E
  • OPT-7103 E ZR

OPT-7104

  • OPT-7104 E
  • OPT-7104 E ZR
  • OPT-7104 NON E TYPE A
  • OPT-7104 NON E ZR TYPE A

OPT-7105

  • OPT-7105 E
  • OPT-7105 E ZR
  • OPT-7105 NON E TYPE A
  • OPT-7105 NON E ZR TYPE A

Clarifying Notes

E = Engaging.
NON E = Non Engaging.
TYPE A = Normal Connection to be used in all designs.
deep = that the design is ready to use the screw **"Basal"**.
ZR = the connection is for zirconium structures

It is advisable to test these options in order to choose the most appropriate to each one when needed.