Difference between revisions of "Zimmer Tapered screw Vent®"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(Undo revision 9022 by L.Pizzoli (talk))
 
(One intermediate revision by the same user not shown)
(No difference)

Latest revision as of 14:40, 9 December 2015

Zimmer Tapered screw Vent®

We have four sizes.

  • OPT-3201 - ∅ 3,5
  • OPT-3202 - ∅ 4,5
  • OPT-3203 - ∅ 5,7
  • OPT-3203 - ∅ Conic ACTR

We have the following options in the Implant Library:

OPT-3201

  • OPT-3201 E
  • OPT-3201 E ZR
  • OPT-3201 NON E TYPE A
  • OPT-3201 NON E ZR TYPE A
  • OPT-3201 NON E TYPE B
  • OPT-3201 NON E ZR TYPE B

OPT-3202

  • OPT-3202 E
  • OPT-3202 E ZR
  • OPT-3202 NON E TYPE A
  • OPT-3202 NON E ZR TYPE A
  • OPT-3202 NON E TYPE B
  • OPT-3202 NON E ZR TYPE B
  • OPT-3202 NON E TYPE C
  • OPT-3202 NON E ZR TYPE C

OPT-3203

  • OPT-3203 E
  • OPT-3203 E ZR
  • OPT-3203 NON E TYPE A
  • OPT-3203 NON E ZR TYPE A
  • OPT-3203 NON E TYPE B
  • OPT-3203 NON E ZR TYPE B

OPT-3204

  • OPT-3204 NON E

Clarifying Notes

E = Engaging.
NON E = Non Engaging.
ZR = When we want to use the library to produce zirconium structures.
TYPE A = the connection is deeper and it is advised to use in cases with good parallelism. (Picture 1.)
TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. (Picture 2.)
TYPE C = the connection is very shorter and it is advisable to use in cases of very bad parallelism. (Picture 3.)

It is advisable to test these options in order to choose the most appropriate to each one when needed.

OPT-3200-img1.jpg