Difference between revisions of "Dentsply Friadent Xive®"
Line 14: | Line 14: | ||
* OPT-2201 NON E TYPE A | * OPT-2201 NON E TYPE A | ||
* OPT-2201 NON E ZR TYPE A | * OPT-2201 NON E ZR TYPE A | ||
+ | * OPT-2201 NON E TYPE B | ||
+ | * OPT-2201 NON E ZR TYPE B | ||
==OPT-2202== | ==OPT-2202== | ||
Line 20: | Line 22: | ||
* OPT-2202 NON E TYPE A | * OPT-2202 NON E TYPE A | ||
* OPT-2202 NON E ZR TYPE A | * OPT-2202 NON E ZR TYPE A | ||
+ | * OPT-2202 NON E TYPE B | ||
+ | * OPT-2202 NON E ZR TYPE B | ||
==OPT-2203== | ==OPT-2203== | ||
Line 26: | Line 30: | ||
* OPT-2203 NON E TYPE A | * OPT-2203 NON E TYPE A | ||
* OPT-2203 NON E ZR TYPE A | * OPT-2203 NON E ZR TYPE A | ||
+ | * OPT-2203 NON E TYPE B | ||
+ | * OPT-2203 NON E ZR TYPE B | ||
==OPT-2204== | ==OPT-2204== | ||
Line 32: | Line 38: | ||
* OPT-2204 NON E TYPE A | * OPT-2204 NON E TYPE A | ||
* OPT-2204 NON E ZR TYPE A | * OPT-2204 NON E ZR TYPE A | ||
+ | * OPT-2204 NON E TYPE B | ||
+ | * OPT-2204 NON E ZR TYPE B | ||
=Clarifying Notes= | =Clarifying Notes= | ||
Line 37: | Line 45: | ||
;NON E = Non Engaging. | ;NON E = Non Engaging. | ||
;ZR = When we want to use the library to produce zirconium structures. | ;ZR = When we want to use the library to produce zirconium structures. | ||
− | ;TYPE A = | + | ;TYPE A = the connection is deeper and it is advised to use in cases with good parallelism. (Picture 1.) |
+ | ;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. (Picture 2.) | ||
It is advisable to test these options in order to choose the most appropriate to each one when needed. | It is advisable to test these options in order to choose the most appropriate to each one when needed. | ||
[[File:OPT-2200-TYPEA.jpg|left|frame|Type A]] | [[File:OPT-2200-TYPEA.jpg|left|frame|Type A]] | ||
+ | [[File:OPT-2200-TYPEB.jpg|left|frame|Type B]] |
Latest revision as of 14:38, 9 December 2015
Contents
Dentsply Friadent Xive®
We have four sizes.
- OPT-2201 - ∅ 3,4
- OPT-2202 - ∅ 3,8
- OPT-2203 - ∅ 4,5
- OPT-2204 - ∅ 5,5
We have the following options in the Implant Library:
OPT-2201
- OPT-2201 E
- OPT-2201 E ZR
- OPT-2201 NON E TYPE A
- OPT-2201 NON E ZR TYPE A
- OPT-2201 NON E TYPE B
- OPT-2201 NON E ZR TYPE B
OPT-2202
- OPT-2202 E
- OPT-2202 E ZR
- OPT-2202 NON E TYPE A
- OPT-2202 NON E ZR TYPE A
- OPT-2202 NON E TYPE B
- OPT-2202 NON E ZR TYPE B
OPT-2203
- OPT-2203 E
- OPT-2203 E ZR
- OPT-2203 NON E TYPE A
- OPT-2203 NON E ZR TYPE A
- OPT-2203 NON E TYPE B
- OPT-2203 NON E ZR TYPE B
OPT-2204
- OPT-2204 E
- OPT-2204 E ZR
- OPT-2204 NON E TYPE A
- OPT-2204 NON E ZR TYPE A
- OPT-2204 NON E TYPE B
- OPT-2204 NON E ZR TYPE B
Clarifying Notes
- E = Engaging.
- NON E = Non Engaging.
- ZR = When we want to use the library to produce zirconium structures.
- TYPE A = the connection is deeper and it is advised to use in cases with good parallelism. (Picture 1.)
- TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism. (Picture 2.)
It is advisable to test these options in order to choose the most appropriate to each one when needed.