Difference between revisions of "Nobel Biocare Replace Select®"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
(Undo revision 9011 by L.Pizzoli (talk))
 
(3 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
= Nobel_Biocare_Replace_Select® =
 
We have four sizes.
 
We have four sizes.
  
Line 6: Line 7:
 
* OPT-1104 - 6.0
 
* OPT-1104 - 6.0
  
We have the following * OPTions in the Implant Library:
+
We have the following options in the Implant Library:
  
* OPT-1101
+
==OPT-1101 ==
 
* OPT-1101 E
 
* OPT-1101 E
 
* OPT-1101 E ZR
 
* OPT-1101 E ZR
Line 16: Line 17:
 
* OPT-1101 NON E ZR TYPE B
 
* OPT-1101 NON E ZR TYPE B
  
* OPT-1102
+
== OPT-1102 ==
 
* OPT-1102 E
 
* OPT-1102 E
 
* OPT-1102 E ZR
 
* OPT-1102 E ZR
Line 24: Line 25:
 
* OPT-1102 NON E ZR TYPE B
 
* OPT-1102 NON E ZR TYPE B
  
* OPT-1103
+
== OPT-1103 ==
 
* OPT-1103 E
 
* OPT-1103 E
 
* OPT-1103 E ZR
 
* OPT-1103 E ZR
Line 32: Line 33:
 
* OPT-1103 NON E ZR TYPE B
 
* OPT-1103 NON E ZR TYPE B
  
* OPT-1104
+
== OPT-1104 ==
 
* OPT-1104 E
 
* OPT-1104 E
 
* OPT-1104 NON E
 
* OPT-1104 NON E
 +
 +
= Clarifying Notes =
 +
 +
;'E' = Engaging.
 +
;NON E = Non Engaging.
 +
;TYPE A = the connection is deeper and it is advised to use in  cases with good parallelism.
 +
;TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
 +
;ZR = the connection is for zirconium structures.
  
 
[[File:OPT-1100-small.jpg|frame|left|Type A]]
 
[[File:OPT-1100-small.jpg|frame|left|Type A]]
 
[[File:OPT-1100-large.jpg|frame|left|Type B]]
 
[[File:OPT-1100-large.jpg|frame|left|Type B]]
 
Clarifying Notes
 
 
;''E'' = Engaging.
 
;''NON E'' = Non Engaging.
 
;''TYPE A'' = the connection is deeper and it is advised to use in  cases with good parallelism.
 
;''TYPE B'' = the connection is shorter and it is advisable to use in cases of bad parallelism.
 
;''ZR'' = the connection is for zirconium structures
 

Latest revision as of 14:36, 9 December 2015

Nobel_Biocare_Replace_Select®

We have four sizes.

  • OPT-1101 - NP
  • OPT-1102 - RP
  • OPT-1103 - WP
  • OPT-1104 - 6.0

We have the following options in the Implant Library:

OPT-1101

  • OPT-1101 E
  • OPT-1101 E ZR
  • OPT-1101 NON E TYPE A
  • OPT-1101 NON E ZR TYPE A
  • OPT-1101 NON E TYPE B
  • OPT-1101 NON E ZR TYPE B

OPT-1102

  • OPT-1102 E
  • OPT-1102 E ZR
  • OPT-1102 NON E TYPE A
  • OPT-1102 NON E ZR TYPE A
  • OPT-1102 NON E TYPE B
  • OPT-1102 NON E ZR TYPE B

OPT-1103

  • OPT-1103 E
  • OPT-1103 E ZR
  • OPT-1103 NON E TYPE A
  • OPT-1103 NON E ZR TYPE A
  • OPT-1103 NON E TYPE B
  • OPT-1103 NON E ZR TYPE B

OPT-1104

  • OPT-1104 E
  • OPT-1104 NON E

Clarifying Notes

'E' = Engaging.
NON E = Non Engaging.
TYPE A = the connection is deeper and it is advised to use in cases with good parallelism.
TYPE B = the connection is shorter and it is advisable to use in cases of bad parallelism.
ZR = the connection is for zirconium structures.
Type A
Type B