Difference between revisions of "Accessories"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
 
Line 97: Line 97:
 
<!--T:39-->
 
<!--T:39-->
 
The Reference Rim offers reference points to grant accurate dimensional results during the scanning process. Although dimensional accuracy is granted for the vast majority of all objects, in case of scanning small metalic objects, such as metal abutments, or other difficult materials, the Reference Rim offers even better results and safety.
 
The Reference Rim offers reference points to grant accurate dimensional results during the scanning process. Although dimensional accuracy is granted for the vast majority of all objects, in case of scanning small metalic objects, such as metal abutments, or other difficult materials, the Reference Rim offers even better results and safety.
 +
 +
'''NOTE THAT THE REFERENCE RIM IS A PRECISION OBJECT! OCCLUSAL AND WHITENING SPRAYS, AND CLEANING SOLVENTS, DAMAGE ITS SURFACE!'''
 +
'''DO NOT SPRAY ANY SUBSTANCE ON THE RIM AS TO DO SO IT WILL NO LONGER BE USABLE FOR SCANNING NOR FOR CALIBRATING!'''
 +
 +
  
 
<!--T:40-->
 
<!--T:40-->

Latest revision as of 10:32, 28 May 2018


Accessories

The Open Technologies' Scanners come with a fixed set of basic accessories and some extra accessories that depend on the specific scanner model.

Base Kit

The Basic Kit comes with every scanner, inside a case, containing the model holder, the multi-die holder and the calibration kit.

Model Holder

The Model Holder is the main support on which it's possible to place jaws or other objects inside the scanner. If mounted on this support, the objects are guaranteed to be in the best possible position for the scanner acquisition.

It's important to keep the model holder clean and black to reduce the possible interferences between the model holder and the object during the acquisition phase.

Model holder big.png Model holder small.png

Multi-Die Support

The Multi-Die support is used to acquire multiple stumps with a single acquisition. The position are later automatically identified by the software.

It's important to keep the Multi-Die clean and black to reduce the possible interferences between the Multi-Die and the object during the acquisition phase.

Model multidie big.png Model multidie small.png

Calibration Kit

The Calibration Kit is a planar surface with a pattern of circles, placed on a bended support.
Every calibration kit is measured and analized with high-precision machines.
The measurement is then saved on a xml file and every kit has it's own xml description file.
The kit is used to recalibrate the optical head of the scanner.

It's really important to handle the kit with care and to avoid touching the planar surface. Every modification of the planar surface, like scratches or dirt, can make the calibration system unreliable.

Calibration kit.jpg

Dynamic Articulation Module

In order to use the dynamic articulation module, some special supports are needed: a specific Axis Calibration Object and a special Mounting Plate for every supported articulator.

Mounting Plates

Up to the present, our dynamic articulation module supports 4 different mounting plates.

  • Artex : Basetta artex.jpg
  • Kavo : Basetta cavo.jpg
  • Adesso : Basetta adesso.jpg
  • Sam : Basetta sam.jpg
  • Bioart : Basetta bioart.jpg
  • Denar : Basetta denar.jpg


Axis Calibration Object

This is a specific object, which fits on every mounting plate, used to calibrate the movement system for the Dynamic Articulation Module.

It's important to keep the object clean and handle it with care. Every modification of the object surface, like scratches or dirt, can make the calibration system unreliable.

Kavo oggettotest.jpg

Concept Quad Support

The Concept Quad Support is provided together with the additional Concept Quad Scanning Module and it allows to place two antagonist quadrant models and their stumps in the scanner to be scanned in together at the same time.

It's important to keep the model holder clean and black to reduce the possible interferences between the model holder and the object during the acquisition phase.

Concept holder big.png Concept holder small.png

Reference Rim

The Reference Rim offers reference points to grant accurate dimensional results during the scanning process. Although dimensional accuracy is granted for the vast majority of all objects, in case of scanning small metalic objects, such as metal abutments, or other difficult materials, the Reference Rim offers even better results and safety.

NOTE THAT THE REFERENCE RIM IS A PRECISION OBJECT! OCCLUSAL AND WHITENING SPRAYS, AND CLEANING SOLVENTS, DAMAGE ITS SURFACE!

DO NOT SPRAY ANY SUBSTANCE ON THE RIM AS TO DO SO IT WILL NO LONGER BE USABLE FOR SCANNING NOR FOR CALIBRATING! 


Reference rim.png

Accessories not provided by Open Technologies

TouchScreen Monitor

Starting version 4.5 OpticalRevEng Dental can be also used with any kind of touchscreen monitor.

3D Mouse

Starting version 4.5 OpticalRevEng Dental can be also controlled with any kind of 3D Mouse.