Difference between revisions of "Dental Options Dental"

From Open Tech Dental Wiki 4.0
Jump to: navigation, search
 
(8 intermediate revisions by 2 users not shown)
Line 8: Line 8:
  
 
<!--T:4-->
 
<!--T:4-->
There are 5 sub-categories:
+
There are 3 sub-categories:
  
 
==General== <!--T:2-->
 
==General== <!--T:2-->
Line 15: Line 15:
 
In the General Page there are:
 
In the General Page there are:
  
<!--T:6-->
+
=== Project Managment === <!--T:6-->
* A project management section with:
 
** '''Scanner Project''' : the path where the software saves all the projects created by the user
 
** '''Auto Save''' : if this option is checked, the software will automatically save the project after every main step (Acquisition, Alignment, Mesh Generation)
 
** '''Min RI sample number''' : the minimum number of points for an acquisition to be valid. Under the threshold, all the acquisitions will be automatically discarded
 
* The Multi-Die Parameters: standard parameters. It is suggested not to modify these parameters but to use the specific multi-die calibration instead.
 
* A wizard options section with:
 
** '''Check Articulator Alignment''' : if this option is checked, the software will show the result of the alignment with the articulation during the Step-By-Step Wizard
 
** '''Show Parallel Mesh Generation''' : if this option is checked, the software will show a function to generate the Meshes during the next scanning step and not at the specific Mesh Generation Step. This function is longer a valid option to speed up the project
 
** '''Stumps Manual Cut''' : if this option is checked, the software will show the user an additional Manual Cut step for every stump in the project
 
* '''Wizard Auto Cut''', where the auto cut function can be enabled/disabled for every supported element
 
  
<!--T:7-->
+
<!--T:16-->
{{Screenshot|Dental_2_5_options_dental_general.jpg}}
+
This section allows to change the way the software handles the information
  
==Prosthesis== <!--T:8-->
+
<!--T:17-->
 +
; Dental Projects : the path where the software saves all the projects created by the user
 +
; External Projects: the path where the software saves the scan data, if the user doesn't want to save it in the Exocad Project Folder.
 +
; Implants : the path where the software will search for the implant libraries
 +
; Usa Numeration Type : if this option is checked, the software will use the Universal Tooth Numbering System
 +
; Auto Save : if this option is checked, the software will automatically save the project after every main step (Acquisition, Alignment, Mesh Generation)
 +
; Compressed Projects : if this option is enabled, the software will compress the projet data saving up to 70% of the space on the disk. The compressed project can not be loaded by previous versions of the software
 +
; Min RI sample number : the minimum number of points for an acquisition to be considered valid. Under the established threshold, all the acquisitions will be automatically discarded
  
<!--T:9-->
+
=== Multi Die Parameter === <!--T:18-->
This page configures how the software integrates with the Exocad CAD Platform or other Prosthesis CAD software. The configurations are:
 
  
<!--T:10-->
+
<!--T:19-->
* A Dental CAD section with:
+
The parameters in this section are specific to the Multi-Die support. It is suggested not to modify these parameters but to use the specific multi-die calibration instead.
** '''Implants''' : the path on the disk with all the implant libraries
 
** '''DentalCad''' : the Exocad ''DentalCadApp.exe'' path, used by the ''Auto Start Dental Cad'' feature
 
** '''Format''' : the format used by the software to export the meshes. For more information, check the [[Man_DataExport#Automatic_Export|Automatic Export]] page
 
* A '''Dental Number Settings''' section with an option to use the US (Universal) teeth numbering scheme instead of the default FDI numbering scheme
 
* A Final Trasformation section, better explained in the [[Man_DataExport#Final_transformation|Final Transformation]] page
 
* Other Options like:
 
** '''Auto Start Dental Cad''' : if this option is checked, OpticalRevEng Dental will automatically start the CAD design after a succesful export to the Exocad CAD Platform
 
** '''Auto Close''' : if this option is checked, OpticalRevEng Dental will be automatically closed after a succesful export to the Exocad CAD Platform
 
** '''Separate Stumps''' : if this option is checked, every stump will be exported as a single file instead of being exported merged together with the rest of the jaw data
 
  
<!--T:11-->
+
<!--T:28-->
{{Screenshot|Dental_2_5_options_dental_protesis.jpg}}
+
{{Screenshot|Dental_3_5_options_dental_general.JPG}}
  
==Orthodontic, Scheletric and Impression== <!--T:12-->
+
== Wizard == <!--T:20-->
  
<!--T:13-->
+
=== Wizard Option === <!--T:21-->
These three tabs are identical but applied to specific '''Structured Projects'''.<br/>
+
This section allows to change the workflow of the Step-By-Step wizard
There are 2 sections:
+
 
 +
<!--T:22-->
 +
; Check Articulator Alignment : if this option is checked, the software will show the result of the alignment with the articulation during the Step-By-Step Wizard
 +
; Show Parallel Mesh Generation : if this option is checked, the software will show a function to generate the Meshes during the next scanning step and not at the specific Mesh Generation Step. This function is longer a valid option to speed up the project
 +
; Stumps Manual Cut : if this option is checked, the software will show the user an additional Manual Cut step for every stump in the project
 +
; Auto Export to Cad: automatically exports the generated STL file to the connected CAD
 +
; Skip Opt Implant Library Alignment: allows to skip the library alingment step to aling the markers to the library in another software
 +
 
 +
=== Wizard Auto Cut === <!--T:23-->
 +
 
 +
<!--T:24-->
 +
This section allows to enable and disable the automatic cut of duplicated surface for the entire Step-By-Step wizard or only for some elements
 +
 
 +
<!--T:29-->
 +
{{Screenshot|Dental_3_5_options_dental_wizard.JPG}}
  
<!--T:14-->
 
*A Path section with:
 
** '''Path''' : the folder where the software will export the data for this specific project. If empty, the data will be exported in the OpticalRevEng Dental Project folder
 
** '''Pattern''' : the directory and the file name format used to save the files on the disk. Some special characters starting with ''%'' will be replaced by specific data coming from the project, as shown in the Legend.
 
* A Final Trasformation section, better explained in the [[Man_DataExport#Final_transformation|Final Transformation]] page
 
  
<!--T:15-->
 
{{Screenshot|Dental_2_5_options_dental_ortho.jpg}}
 
 
</translate>
 
</translate>
 
{{Navigation|Dental_Options_Global|Dental_Options_Interactor}}
 
{{Navigation|Dental_Options_Global|Dental_Options_Interactor}}

Latest revision as of 14:02, 29 August 2016


Dental

This options section provides information on how the Step-By-Step wizard works, how to integrate the software with other CAD systems and how to configure the automatic export system for the structured projects.

There are 3 sub-categories:

General

In the General Page there are:

Project Managment

This section allows to change the way the software handles the information

Dental Projects 
the path where the software saves all the projects created by the user
External Projects
the path where the software saves the scan data, if the user doesn't want to save it in the Exocad Project Folder.
Implants 
the path where the software will search for the implant libraries
Usa Numeration Type 
if this option is checked, the software will use the Universal Tooth Numbering System
Auto Save 
if this option is checked, the software will automatically save the project after every main step (Acquisition, Alignment, Mesh Generation)
Compressed Projects 
if this option is enabled, the software will compress the projet data saving up to 70% of the space on the disk. The compressed project can not be loaded by previous versions of the software
Min RI sample number 
the minimum number of points for an acquisition to be considered valid. Under the established threshold, all the acquisitions will be automatically discarded

Multi Die Parameter

The parameters in this section are specific to the Multi-Die support. It is suggested not to modify these parameters but to use the specific multi-die calibration instead.

Dental 3 5 options dental general.JPG

Wizard

Wizard Option

This section allows to change the workflow of the Step-By-Step wizard

Check Articulator Alignment 
if this option is checked, the software will show the result of the alignment with the articulation during the Step-By-Step Wizard
Show Parallel Mesh Generation 
if this option is checked, the software will show a function to generate the Meshes during the next scanning step and not at the specific Mesh Generation Step. This function is longer a valid option to speed up the project
Stumps Manual Cut 
if this option is checked, the software will show the user an additional Manual Cut step for every stump in the project
Auto Export to Cad
automatically exports the generated STL file to the connected CAD
Skip Opt Implant Library Alignment
allows to skip the library alingment step to aling the markers to the library in another software

Wizard Auto Cut

This section allows to enable and disable the automatic cut of duplicated surface for the entire Step-By-Step wizard or only for some elements

Dental 3 5 options dental wizard.JPG


Dental 2 5 wiz prev.png Homebutton.png Dental 2 5 wiz next.png