
<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://wiki.opentechdental.com/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=FrancescoMRomano</id>
		<title>Open Tech Dental Wiki 4.0 - User contributions [en]</title>
		<link rel="self" type="application/atom+xml" href="https://wiki.opentechdental.com/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=FrancescoMRomano"/>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/wiki/Special:Contributions/FrancescoMRomano"/>
		<updated>2026-04-07T18:04:53Z</updated>
		<subtitle>User contributions</subtitle>
		<generator>MediaWiki 1.30.0</generator>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17216</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17216"/>
				<updated>2016-02-03T11:05:17Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Um diese Funktion zu starten, auf diesen {{Inline button|actionDiagnosticAcquisition.svg}}  Knopf klicken.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Automatisches Setup der Multi-Die Parameter==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung wie folgt:&lt;br /&gt;
&lt;br /&gt;
# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein. &lt;br /&gt;
# Den leeren Multi-Die-Halter in den Scanner legen&lt;br /&gt;
# Das Werkzeug “Automatischer Setup der Multi-Die Parameter” durch das Klicken auf diesen  {{Inline button|ActionAutoSetUpMultiDieParameters.svg }}  Knopf starten&lt;br /&gt;
# Wenn gefragt, auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
==Diagnosescanbild==&lt;br /&gt;
&lt;br /&gt;
Wenn man das korrekte Funktionieren des Scanners in Frage stellt, ist es möglich, ein Objekt zu scannen und dessen entsprechende Informationen im “*.diag”-Format zu speichern.&lt;br /&gt;
&lt;br /&gt;
Dieses File kann dann dem Supportteam von OpticalRevEng Dental zugeschickt werden, das es analysiert und mögliche Probleme diagnostiziert.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu starten, auf diesen {{Inline button|actionDiagnosticAcquisition.svg}}  Knopf klicken.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/34/de&amp;diff=17215</id>
		<title>Translations:Dental Service Tools/34/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/34/de&amp;diff=17215"/>
				<updated>2016-02-03T11:05:15Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Um diese Funktion zu starten, auf diesen {{Inline button|actionDiagnosticAcquisition.svg}}  Knopf klicken.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Um diese Funktion zu starten, auf diesen {{Inline button|actionDiagnosticAcquisition.svg}}  Knopf klicken.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/33/de&amp;diff=17213</id>
		<title>Translations:Dental Service Tools/33/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/33/de&amp;diff=17213"/>
				<updated>2016-02-03T11:04:50Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses File kann dann dem Supportteam von OpticalRevEng Dental zugeschickt werden, das es analysiert und mögliche Probleme diagnostiziert.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dieses File kann dann dem Supportteam von OpticalRevEng Dental zugeschickt werden, das es analysiert und mögliche Probleme diagnostiziert.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17214</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17214"/>
				<updated>2016-02-03T11:04:50Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses File kann dann dem Supportteam von OpticalRevEng Dental zugeschickt werden, das es analysiert und mögliche Probleme diagnostiziert.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Automatisches Setup der Multi-Die Parameter==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung wie folgt:&lt;br /&gt;
&lt;br /&gt;
# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein. &lt;br /&gt;
# Den leeren Multi-Die-Halter in den Scanner legen&lt;br /&gt;
# Das Werkzeug “Automatischer Setup der Multi-Die Parameter” durch das Klicken auf diesen  {{Inline button|ActionAutoSetUpMultiDieParameters.svg }}  Knopf starten&lt;br /&gt;
# Wenn gefragt, auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
==Diagnosescanbild==&lt;br /&gt;
&lt;br /&gt;
Wenn man das korrekte Funktionieren des Scanners in Frage stellt, ist es möglich, ein Objekt zu scannen und dessen entsprechende Informationen im “*.diag”-Format zu speichern.&lt;br /&gt;
&lt;br /&gt;
Dieses File kann dann dem Supportteam von OpticalRevEng Dental zugeschickt werden, das es analysiert und mögliche Probleme diagnostiziert.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/21/de&amp;diff=17211</id>
		<title>Translations:Dental Service Tools/21/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/21/de&amp;diff=17211"/>
				<updated>2016-02-03T11:04:43Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Wenn man das korrekte Funktionieren des Scanners in Frage stellt, ist es möglich, ein Objekt zu scannen und dessen entsprechende Informationen im “*.diag”-Format zu speic...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Wenn man das korrekte Funktionieren des Scanners in Frage stellt, ist es möglich, ein Objekt zu scannen und dessen entsprechende Informationen im “*.diag”-Format zu speichern.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17212</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17212"/>
				<updated>2016-02-03T11:04:43Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Wenn man das korrekte Funktionieren des Scanners in Frage stellt, ist es möglich, ein Objekt zu scannen und dessen entsprechende Informationen im “*.diag”-Format zu speic...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Automatisches Setup der Multi-Die Parameter==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung wie folgt:&lt;br /&gt;
&lt;br /&gt;
# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein. &lt;br /&gt;
# Den leeren Multi-Die-Halter in den Scanner legen&lt;br /&gt;
# Das Werkzeug “Automatischer Setup der Multi-Die Parameter” durch das Klicken auf diesen  {{Inline button|ActionAutoSetUpMultiDieParameters.svg }}  Knopf starten&lt;br /&gt;
# Wenn gefragt, auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
==Diagnosescanbild==&lt;br /&gt;
&lt;br /&gt;
Wenn man das korrekte Funktionieren des Scanners in Frage stellt, ist es möglich, ein Objekt zu scannen und dessen entsprechende Informationen im “*.diag”-Format zu speichern.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17210</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17210"/>
				<updated>2016-02-03T11:04:35Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Automatisches Setup der Multi-Die Parameter==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung wie folgt:&lt;br /&gt;
&lt;br /&gt;
# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein. &lt;br /&gt;
# Den leeren Multi-Die-Halter in den Scanner legen&lt;br /&gt;
# Das Werkzeug “Automatischer Setup der Multi-Die Parameter” durch das Klicken auf diesen  {{Inline button|ActionAutoSetUpMultiDieParameters.svg }}  Knopf starten&lt;br /&gt;
# Wenn gefragt, auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
==Diagnosescanbild==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/20/de&amp;diff=17209</id>
		<title>Translations:Dental Service Tools/20/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/20/de&amp;diff=17209"/>
				<updated>2016-02-03T11:04:34Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Diagnosescanbild==&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/20/de&amp;diff=17208</id>
		<title>Translations:Dental Service Tools/20/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/20/de&amp;diff=17208"/>
				<updated>2016-02-03T11:04:25Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;==Diagnostic Acquisition==&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Diagnostic Acquisition==&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17207</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17207"/>
				<updated>2016-02-03T11:04:19Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein.  # Den leeren Multi-Die-Halter in den Scanne...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Automatisches Setup der Multi-Die Parameter==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung wie folgt:&lt;br /&gt;
&lt;br /&gt;
# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein. &lt;br /&gt;
# Den leeren Multi-Die-Halter in den Scanner legen&lt;br /&gt;
# Das Werkzeug “Automatischer Setup der Multi-Die Parameter” durch das Klicken auf diesen  {{Inline button|ActionAutoSetUpMultiDieParameters.svg }}  Knopf starten&lt;br /&gt;
# Wenn gefragt, auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/19/de&amp;diff=17206</id>
		<title>Translations:Dental Service Tools/19/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/19/de&amp;diff=17206"/>
				<updated>2016-02-03T11:04:18Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein.  # Den leeren Multi-Die-Halter in den Scanne...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;# Den Multi-Die-Halter von Abfallmaterial oder Staub säubern: Jede einzelne Position muss sichtbar von den anderen getrennt sein. &lt;br /&gt;
# Den leeren Multi-Die-Halter in den Scanner legen&lt;br /&gt;
# Das Werkzeug “Automatischer Setup der Multi-Die Parameter” durch das Klicken auf diesen  {{Inline button|ActionAutoSetUpMultiDieParameters.svg }}  Knopf starten&lt;br /&gt;
# Wenn gefragt, auf '''OK''' klicken&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17205</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17205"/>
				<updated>2016-02-03T11:03:46Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung w...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Automatisches Setup der Multi-Die Parameter==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung wie folgt:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/18/de&amp;diff=17204</id>
		<title>Translations:Dental Service Tools/18/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/18/de&amp;diff=17204"/>
				<updated>2016-02-03T11:03:45Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung w...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dieses Werkzeug dient zur Kalibrierung des Multi-Die-Halters. Wenn die durch den Multi-Die-Halter gewonnenen Scanbilder nicht korrekt erkannt werden, läuft die Kalibrierung wie folgt:&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17203</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17203"/>
				<updated>2016-02-03T11:03:43Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;==Automatisches Setup der Multi-Die Parameter==&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Automatisches Setup der Multi-Die Parameter==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/17/de&amp;diff=17202</id>
		<title>Translations:Dental Service Tools/17/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/17/de&amp;diff=17202"/>
				<updated>2016-02-03T11:03:42Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;==Automatisches Setup der Multi-Die Parameter==&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Automatisches Setup der Multi-Die Parameter==&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/16/de&amp;diff=17200</id>
		<title>Translations:Dental Service Tools/16/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/16/de&amp;diff=17200"/>
				<updated>2016-02-03T11:03:32Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt *'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17201</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17201"/>
				<updated>2016-02-03T11:03:32Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt *'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Achsenkalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Achsenkalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/15/de&amp;diff=17198</id>
		<title>Translations:Dental Service Tools/15/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/15/de&amp;diff=17198"/>
				<updated>2016-02-03T11:03:24Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17199</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17199"/>
				<updated>2016-02-03T11:03:24Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
Der Rekalibrierungsvorgang erfolgt automatisch. Danach zeigt die Software eine der folgenden Nachrichten:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17197</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17197"/>
				<updated>2016-02-03T11:03:19Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;# Kalibrierungsobjekt in den Scanner legen # '''Achsen rekalibrieren''' auswählen # Auf '''OK''' klicken&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/14/de&amp;diff=17196</id>
		<title>Translations:Dental Service Tools/14/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/14/de&amp;diff=17196"/>
				<updated>2016-02-03T11:03:18Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;# Kalibrierungsobjekt in den Scanner legen # '''Achsen rekalibrieren''' auswählen # Auf '''OK''' klicken&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;# Kalibrierungsobjekt in den Scanner legen&lt;br /&gt;
# '''Achsen rekalibrieren''' auswählen&lt;br /&gt;
# Auf '''OK''' klicken&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17195</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17195"/>
				<updated>2016-02-03T11:02:50Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden Achsenkalibrierungsobjekt kalibriert werden....&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/13/de&amp;diff=17194</id>
		<title>Translations:Dental Service Tools/13/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/13/de&amp;diff=17194"/>
				<updated>2016-02-03T11:02:49Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden Achsenkalibrierungsobjekt kalibriert werden....&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Important|Wenn das '''dynamische Artikulationsmodell''' aktiviert ist, müssen die Achsen mit dem entsprechenden [[Accessories|Achsenkalibrierungsobjekt]] kalibriert werden. Alle folgende Rekalibrierungen müssen dann mit dem gleichen Objekt durchgeführt werden, sonst wird die Achsenkalibrierung scheitern.}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17193</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17193"/>
				<updated>2016-02-03T11:02:04Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/32/de&amp;diff=17192</id>
		<title>Translations:Dental Service Tools/32/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/32/de&amp;diff=17192"/>
				<updated>2016-02-03T11:02:03Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dieses Tool startet automatisch nach einem &amp;quot;Scannerkopfkalibrierung&amp;quot; oder kann manuell durch diesen {{Inline button|actionDirectAxesCalib.svg}} Knopf gestartet werden.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17191</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17191"/>
				<updated>2016-02-03T11:01:06Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/12/de&amp;diff=17190</id>
		<title>Translations:Dental Service Tools/12/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/12/de&amp;diff=17190"/>
				<updated>2016-02-03T11:01:05Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dieses Werkzeug steuert das Bewegungssystem des Scanners. Ein Objekt wird erfasst und analysiert und die aus diesem Vorgang entstehende Daten werden dann für die Kalibrierung des Bewegungssystem verwendet.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/11/de&amp;diff=17188</id>
		<title>Translations:Dental Service Tools/11/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/11/de&amp;diff=17188"/>
				<updated>2016-02-03T11:01:00Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;==Achsenkalibrierung==&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;==Achsenkalibrierung==&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17189</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17189"/>
				<updated>2016-02-03T11:01:00Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;==Achsenkalibrierung==&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Achsenkalibrierung==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/10/de&amp;diff=17186</id>
		<title>Translations:Dental Service Tools/10/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/10/de&amp;diff=17186"/>
				<updated>2016-02-03T11:00:52Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17187</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17187"/>
				<updated>2016-02-03T11:00:52Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
Im Fall einer erfolgreichen Rekalibrierung, führt die Software eine '''Achsenkalibrierung''' automatisch aus.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/9/de&amp;diff=17184</id>
		<title>Translations:Dental Service Tools/9/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/9/de&amp;diff=17184"/>
				<updated>2016-02-03T11:00:39Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren *'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt *'Rekalibrieru...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17185</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17185"/>
				<updated>2016-02-03T11:00:39Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren *'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt *'Rekalibrieru...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner wurde bereits kalibriert': es ist nicht notwendig, zu kalibrieren&lt;br /&gt;
*'Rekalibrierung erfolgreich ausgeführt': die Rekalibrierung wurde vervollständigt&lt;br /&gt;
*'Rekalibrierung nicht erfolgreich': die Rekalibrierung muss wiederholt werden &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/8/de&amp;diff=17182</id>
		<title>Translations:Dental Service Tools/8/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/8/de&amp;diff=17182"/>
				<updated>2016-02-03T11:00:23Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17183</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17183"/>
				<updated>2016-02-03T11:00:23Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
Die Rekalibrierung erfolgt automatisch. Nach dem Beenden des Vorgangs, zeigt die Software eine der folgenden Nachrichten an:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/7/de&amp;diff=17181</id>
		<title>Translations:Dental Service Tools/7/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/7/de&amp;diff=17181"/>
				<updated>2016-02-03T11:00:18Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;{{Small image|Calib-dlg.jpg}}&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Small image|Calib-dlg.jpg}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/6/de&amp;diff=17179</id>
		<title>Translations:Dental Service Tools/6/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/6/de&amp;diff=17179"/>
				<updated>2016-02-03T11:00:13Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File vo...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17180</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17180"/>
				<updated>2016-02-03T11:00:13Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File vo...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
Wenn das .xml-File des Kalibrierungskit im Dropdownmenü nicht zu finden ist, ist es möglich, die Funkion '''Load New Master Xml''' zu benutzen, um das geeignete .xml-File von einem PC Ordner auszuwählen.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/5/de&amp;diff=17177</id>
		<title>Translations:Dental Service Tools/5/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/5/de&amp;diff=17177"/>
				<updated>2016-02-03T10:59:48Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen #Scankopf rekalibrieren im Werkzeug-Menü auswählen #Im Kalibrierungs-Dialogmenü, das kalibrie...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17178</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17178"/>
				<updated>2016-02-03T10:59:48Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen #Scankopf rekalibrieren im Werkzeug-Menü auswählen #Im Kalibrierungs-Dialogmenü, das kalibrie...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Das Kalibrierungsmuster in den Scanner bzw. in die richtige Position einlegen&lt;br /&gt;
#Scankopf rekalibrieren im Werkzeug-Menü auswählen&lt;br /&gt;
#Im Kalibrierungs-Dialogmenü, das kalibrierungsmusterspezifische .xml File vom Dropdownmenü auswählen&lt;br /&gt;
#Auf '''Start''' klicken&lt;br /&gt;
&lt;br /&gt;
If the calibration kit name is not available in the drop down menu, the '''Load New Master Xml''' button can be used to add a new calibration kit from the appropriate Xml description file.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/4/de&amp;diff=17175</id>
		<title>Translations:Dental Service Tools/4/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/4/de&amp;diff=17175"/>
				<updated>2016-02-03T10:59:28Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Werkzeug verwendet das Kalibrierungskit, um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17176</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17176"/>
				<updated>2016-02-03T10:59:28Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Dieses Werkzeug verwendet das Kalibrierungskit, um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
Dieses Werkzeug verwendet das [[Accessories|Kalibrierungskit]], um den optischen Scankopf zu rekalibrieren. Der Vorgang läuft wie folgt ab:&lt;br /&gt;
&lt;br /&gt;
#Put the calibration kit inside the scanner in the correct position&lt;br /&gt;
#Select the calibration type from the drop-down menu&lt;br /&gt;
#In the calibration dialog, select from the drop down menu the exact calibration kit name&lt;br /&gt;
#Click '''Start'''&lt;br /&gt;
&lt;br /&gt;
If the calibration kit name is not available in the drop down menu, the '''Load New Master Xml''' button can be used to add a new calibration kit from the appropriate Xml description file.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/31/de&amp;diff=17173</id>
		<title>Translations:Dental Service Tools/31/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/31/de&amp;diff=17173"/>
				<updated>2016-02-03T10:59:11Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17174</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17174"/>
				<updated>2016-02-03T10:59:11Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
.&lt;br /&gt;
&lt;br /&gt;
This tool uses the [[Accessories|Calibration Kit]] to carry out a new calibration of the Optical Head of the scanner. The procedure is the following:&lt;br /&gt;
&lt;br /&gt;
#Put the calibration kit inside the scanner in the correct position&lt;br /&gt;
#Select the calibration type from the drop-down menu&lt;br /&gt;
#In the calibration dialog, select from the drop down menu the exact calibration kit name&lt;br /&gt;
#Click '''Start'''&lt;br /&gt;
&lt;br /&gt;
If the calibration kit name is not available in the drop down menu, the '''Load New Master Xml''' button can be used to add a new calibration kit from the appropriate Xml description file.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/30/de&amp;diff=17171</id>
		<title>Translations:Dental Service Tools/30/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/30/de&amp;diff=17171"/>
				<updated>2016-02-03T10:58:03Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17172</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17172"/>
				<updated>2016-02-03T10:58:03Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf diesen {{Inline button|actionRecalibrateHead.svg}} Knopf klicken;&lt;br /&gt;
&lt;br /&gt;
There are 2 types of calibration:&lt;br /&gt;
; Recalibration : Fast procedure to update scanner's calibration periodically or to be performed if the scanner is moved to any other location&lt;br /&gt;
; Full Calibration : More complex procedure to be performed after a mechanical repair&lt;br /&gt;
&lt;br /&gt;
This tool uses the [[Accessories|Calibration Kit]] to carry out a new calibration of the Optical Head of the scanner. The procedure is the following:&lt;br /&gt;
&lt;br /&gt;
#Put the calibration kit inside the scanner in the correct position&lt;br /&gt;
#Select the calibration type from the drop-down menu&lt;br /&gt;
#In the calibration dialog, select from the drop down menu the exact calibration kit name&lt;br /&gt;
#Click '''Start'''&lt;br /&gt;
&lt;br /&gt;
If the calibration kit name is not available in the drop down menu, the '''Load New Master Xml''' button can be used to add a new calibration kit from the appropriate Xml description file.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17170</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17170"/>
				<updated>2016-02-03T10:57:39Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;== Scankopf rekalibrieren ==&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Scankopf rekalibrieren ==&lt;br /&gt;
&lt;br /&gt;
To launch this tool, click on the {{Inline button|actionRecalibrateHead.svg}} button;&lt;br /&gt;
&lt;br /&gt;
There are 2 types of calibration:&lt;br /&gt;
; Recalibration : Fast procedure to update scanner's calibration periodically or to be performed if the scanner is moved to any other location&lt;br /&gt;
; Full Calibration : More complex procedure to be performed after a mechanical repair&lt;br /&gt;
&lt;br /&gt;
This tool uses the [[Accessories|Calibration Kit]] to carry out a new calibration of the Optical Head of the scanner. The procedure is the following:&lt;br /&gt;
&lt;br /&gt;
#Put the calibration kit inside the scanner in the correct position&lt;br /&gt;
#Select the calibration type from the drop-down menu&lt;br /&gt;
#In the calibration dialog, select from the drop down menu the exact calibration kit name&lt;br /&gt;
#Click '''Start'''&lt;br /&gt;
&lt;br /&gt;
If the calibration kit name is not available in the drop down menu, the '''Load New Master Xml''' button can be used to add a new calibration kit from the appropriate Xml description file.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/3/de&amp;diff=17169</id>
		<title>Translations:Dental Service Tools/3/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/3/de&amp;diff=17169"/>
				<updated>2016-02-03T10:57:38Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;== Scankopf rekalibrieren ==&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Scankopf rekalibrieren ==&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17168</id>
		<title>Dental Service Tools/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Dental_Service_Tools/de&amp;diff=17168"/>
				<updated>2016-02-03T10:57:30Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Language bar}}&lt;br /&gt;
{{DISPLAYTITLE:Dental Service Mode|noerror}}&lt;br /&gt;
__TOC__&lt;br /&gt;
&lt;br /&gt;
OpticalRevEng Dental verfügt über verschiedene Analyse- und Rekalibrierungswerkzeuge, die im [[Support_Toolbars_And_Menus#Tools|Werkzeug-Menü ]] zu finden sind, um den Scanner zu rekalibrieren und eine Fehlerdiagnose durchzuführen.&lt;br /&gt;
&lt;br /&gt;
{{Screenshot|Service-mode.jpg}}&lt;br /&gt;
&lt;br /&gt;
== Live Mode ==&lt;br /&gt;
&lt;br /&gt;
Durch dieses Werkzeug ist es möglich, eine Liveübertragung der Scannerkamera zu aktivieren.&lt;br /&gt;
&lt;br /&gt;
Um diese Funktion zu aktivieren, auf {{Inline button|ActionLiveCameraParams.svg}}  klicken.&lt;br /&gt;
&lt;br /&gt;
== Check Scanner ==&lt;br /&gt;
&lt;br /&gt;
Die Software überprüft, ob der Scanneranschluss in Ordnung ist jedes Mal, wenn er aktiviert wird. &lt;br /&gt;
&lt;br /&gt;
Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;br /&gt;
&lt;br /&gt;
== Recalibrate Head==&lt;br /&gt;
&lt;br /&gt;
To launch this tool, click on the {{Inline button|actionRecalibrateHead.svg}} button;&lt;br /&gt;
&lt;br /&gt;
There are 2 types of calibration:&lt;br /&gt;
; Recalibration : Fast procedure to update scanner's calibration periodically or to be performed if the scanner is moved to any other location&lt;br /&gt;
; Full Calibration : More complex procedure to be performed after a mechanical repair&lt;br /&gt;
&lt;br /&gt;
This tool uses the [[Accessories|Calibration Kit]] to carry out a new calibration of the Optical Head of the scanner. The procedure is the following:&lt;br /&gt;
&lt;br /&gt;
#Put the calibration kit inside the scanner in the correct position&lt;br /&gt;
#Select the calibration type from the drop-down menu&lt;br /&gt;
#In the calibration dialog, select from the drop down menu the exact calibration kit name&lt;br /&gt;
#Click '''Start'''&lt;br /&gt;
&lt;br /&gt;
If the calibration kit name is not available in the drop down menu, the '''Load New Master Xml''' button can be used to add a new calibration kit from the appropriate Xml description file.&lt;br /&gt;
&lt;br /&gt;
{{Small image|Calib-dlg.jpg}}&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Scanner Already Calibrated' : the calibration is not necessary&lt;br /&gt;
*'Scanner Recalibrated Successfully' : the calibration has been completed&lt;br /&gt;
*'Scanner Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
If the calibration was successful, the '''Axes Calibration''' starts automatically.&lt;br /&gt;
&lt;br /&gt;
==Recalibrate Axis==&lt;br /&gt;
&lt;br /&gt;
This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.&lt;br /&gt;
&lt;br /&gt;
This tool will start automatically after a '''Head Recalibration''' or can be started manually with the {{Inline button|actionDirectAxesCalib.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Important|When the '''Dynamic Articulation Module''' is enabled, calibrate the axis with the specific [[Accessories|Axis Calibration Object]]. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.}}&lt;br /&gt;
&lt;br /&gt;
# Put the calibration object inside the scanner&lt;br /&gt;
# Click '''Recalibrate Axis'''&lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:&lt;br /&gt;
&lt;br /&gt;
*'Axis Recalibration Successfull' : the calibration has been completed&lt;br /&gt;
*'Axis Recalibration Failed' : calibration has to be repeated &lt;br /&gt;
&lt;br /&gt;
==Auto Set-Up Multi-Die Parameters==&lt;br /&gt;
&lt;br /&gt;
This tool is used to calibrate the Multi-Die support. If the acquisitions carried out with the Multi-Die are not correctly recognized, the calibration procedure is the following:&lt;br /&gt;
&lt;br /&gt;
# Clean the multi-die from excessive material or white powder, every single die position needs to be clearly separated from the others&lt;br /&gt;
# Put the empty multi-die support inside the scanner&lt;br /&gt;
# Start the tool with this button {{Inline button|ActionAutoSetUpMultiDieParameters.svg }} &lt;br /&gt;
# Click '''Ok''' when prompted&lt;br /&gt;
&lt;br /&gt;
==Diagnostic Acquisition==&lt;br /&gt;
&lt;br /&gt;
When doubting the proper functioning of the scanner, this tool carries out a specific acquisition of the object currently inside the scanner.&lt;br /&gt;
&lt;br /&gt;
The software then saves all the information in a &amp;quot;*.diag&amp;quot; file that can be sent to the OpticalRevEng Dental support to diagnose possible issues.&lt;br /&gt;
&lt;br /&gt;
To start this tool click the {{Inline button|actionDiagnosticAcquisition.svg}} button.&lt;br /&gt;
&lt;br /&gt;
{{Navigation|Dental_Options_Interactor|Main Page}}&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	<entry>
		<id>https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/29/de&amp;diff=17167</id>
		<title>Translations:Dental Service Tools/29/de</title>
		<link rel="alternate" type="text/html" href="https://wiki.opentechdental.com/w/index.php?title=Translations:Dental_Service_Tools/29/de&amp;diff=17167"/>
				<updated>2016-02-03T10:57:28Z</updated>
		
		<summary type="html">&lt;p&gt;FrancescoMRomano: Created page with &amp;quot;Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Es ist durch dieses Werkzeug {{Inline button|actionCheckScannerHardware.svg}} möglich, diese Überprüfung manuell zu starten.&lt;/div&gt;</summary>
		<author><name>FrancescoMRomano</name></author>	</entry>

	</feed>